ProVision 3 Installation Manual
8100-35521-00
Rev. A1
Leidos Security Detection & Automation, Inc.
–
Proprietary
Page 16 of 119
© 2020 Leidos. All rights reserved
Figure 2: Belt-Drive Safety Labels
2.4
Toxic Safety Precautions
The consumable materials listed below are toxic to the skin, eyes, and respiratory tract. Good hygiene
practice is recommended; wash your hands thoroughly after leaving your work area. Wear nitrile gloves
and safety glasses when handling the consumable materials:
Isopropyl alcohol
Electrostatic discharge (ESD) wipes [490-26003]
Material safety data sheets are available. Consult your local safety and health staff concerning any
questions about toxic hazards.
2.5
Fire Safety Precaution
In the event of a fire, a Halon fire extinguisher or comparable type is recommended to extinguish any fire
inside the ProVision 3 scanner. Any ABC dry chemical fire extinguisher can be used; however, it may
cause additional damage to the equipment.
2.6
Safety Features
The ProVision 3 scanner is specifically designed to prevent injury during operation or maintenance
procedures. Injury can be avoided by using the electrical power switch to remove power from the
scanner, as discussed in the following paragraph.
The power switch, located at either the lower left or upper right of the outer radome with the posing figure
(see following figure), removes all electrical power from the ProVision 3 scanner. In case of an electrical
emergency:
1.
Press the portion of the power switch labeled
“
O
”
to remove all power from the scanner.
2.
Unplug the power cord from the electrical outlet.
Figure 3: Electrical Power Switch (Two Options)