67
6. Error List
!! ATTENTION!!
*******************************************************
It means fire put out automatically during the
operation, when the exhaust gas temperature
is below 40-45degree.
Such as: 1. There has no fuel at hopper.
2. Auger motor is broken and stop feeding the fuel.
It means Igniter failure at the beginning.
Such as: 1. there have clinkers in fire pot.
2.
The fire pot has not put right.
3.
The switch which is located beside the
combustion fan to test the exhaust gas
temperature
sensor, is broken,
4.
The igniter is broken
It means there is earthquake during the
operation time. or You tilt the stove. Only for
the Japan version
Problem for the temperature sensor.
Unplug or broken or water temperature is too high
(This function only for the pellet stove with hot
water)
It means that there are some problems with vacuum
Switch.
Such as door has not been closed properly;
Combustion fan's speed cannot Speed up;
There is some leakage about the stove or
exhaust pipe is blocked and so on.
It means that the high temperature sensor
,
which is located below the hopper, has some
problem, such as: 1. the switch is broken, 2. The
temperature is too high that the stove runs not
properly
During the operation, the stove is interrupted by
electronic cut.
It means you need to clean the stoves.
If check everything is fine, you can press
to delete the Error code
Summary of Contents for LF-29-13BM
Page 1: ...1 Salamandra a Pellets LF 29 13CZ BR BM ...
Page 2: ...2 Índice Index Indice Português 3 English 42 Français 84 ...
Page 11: ...11 ...
Page 40: ...40 ...
Page 41: ...41 9 Plano Electrónico ...
Page 51: ...51 ...
Page 73: ...73 End of the season maintenance ...
Page 83: ...83 10 Electronic Plan ...
Page 92: ...92 ...
Page 120: ...120 10 Carte électronique ...