NOVOLAS Basic AT
Version 2.1
09/2010
24
Interfaces
4.3.4 Analogue Inputs (X16)
General specification:
•
Voltage range 0 to 10 Volt
•
Impedance app. 50 kOhm
•
Maximum voltage 35 Volt
•
Attention! Common reference potential with analogue outputs and
serial ports
Terminal
Description
Potential
X16.1
Signal Common GND
X16.2
Modulation signal Laser Unit#B (#D) (optional)
X16.3
Modulation signal Laser Unit#A (#C) (optional)
X16.4
Current preset laser unit #B (#D),
(usually 1V per 10A)
X16.5
Current preset laser unit #A (#C),
(usually 1V per 10A.)
4.3.5 Analogue Outputs (X17)
General specification:
•
Voltage range 0 to 10 Volt
•
Impedance app. 10 kOhm
•
Max. Output current 1mA
•
Attention! Common reference potential with analogue inputs and
serial ports
Terminal
Beschreibung
Potential
X17.1
Signal Common GND
X17.2
Pyrometer signal Laser Unit#B (#D) (optional)
X17.3
Pyrometer signal Laser Unit#A (#C) (optional)
X17.4
Current feedback Laser Unit #B (#D)
(typisch 1V pro 10A)
X17.5
Current feedback Laser Unit #A (#C)
(typisch 1V pro 10A)