NOVOLAS Basic AT
Version 2.1
09/2010
34
Installation
Step
Signal wiring
Remark
3.1
Supply Customer I/O to an external 24V supply
4.3
3.2
Install external emission warning device (not supplied)
corresponding to EN60825 4.6. For this purpose two
independent 24V signals are available on X90.7-9.
X90.7 and X90.8 is activated when the laser current
source is powered (System started and laser key switch
in on position). It is suggested to use the individual laser
emitting signals (X15.8 and X15.5) only to signal actual
laser activation, since an activation of this signal means
that the laser is active and the dangerous situation is
already actuated.
4.1 , 4.3.2
3.3
Install external emergency stop switches on terminals
X90.3/4 and X90.5/6 such that a system stop in case of
an emergency is feasible at every possible moment. If no
additional emergency stop is used, X90.3-X90.4 and
X90.5-X90.6 have to be bridged.
4.2.1
3.4
Connect external interlock switches on terminals X91...
for each laser unit. The interlock circuit must be installed.
Always use both channels and do not short the channels.
4.2.2
Do not bridge!
Never operate the
NOVOLAS Basic AT system
with defeated interlock.
3.5
In default mode the gate and the trigger-signal must be
connected to the Customer I/O's digital inputs supplied
by an external 24V supply. The current will be set by an
analogue voltage on the analogue inputs of the
Customer I/O.
6.3
Depending on the operation
mode. Operation mode
can be reprogrammed by
the RS232 interface.
Step
Each Laser Unit
Remark
4.1
Install optical fiber connectors. The laser modules can
be easily accessed from the right side. They must be well
tightened. Never operate the laser system without the
optical fiber installed.
See Module Manual of the
according optic and
Figure 10.
4.2
Lead fiber and signal cable to processing optics.
Check minimum radius of
curvature (>200 mm for the
SMA and >250 mm for the
HiYAG fiber). Make sure this
is respected in all positions of
a positioning system!
4.3
120 W, 200 W fiber coupled laser modules: Install
purge air supply to the NOVOLAS Basic AT.
Must be dry, clean and
completely oil-free to avoid
condensation.
Tube has an external
diameter of 6 mm.
Synthetic air, min. purity N57,
flow rate 0.1...0.5l/h