NOVOLAS Basic AT
Version 2.1
09/2010
60
Technical Data
10 Technical Data
10.1 Installation data
Before switching on, ensure that the machine is supplied with the correct mains
voltage.
Voltage
230 VAC ± 10%, (200VAC ± 10% optional)
Frequency
50 Hz ± 1% or 60 Hz ± 1%
Max. current
max. 16 A
Max. power consumption
3600 W
Required external Fuse
protection
16 A (slow-blow)
Internal fuses
4 pieces 8A/250V, slow blow, size 5x20mm
(4-optic modules: F3 und F4 10A/250V, slow blow)
Mains cable (supplied)
3 m; wires: 2.5 mm2
10.2 Dimensions and weight
Dimensions
(width x length x height)
Height can be increased in
4HE steps up to 25HE
550 mm x 780 mm x ca. 700 mm (12HE Version)
550 mm x 780 mm x ca. 878 mm (16HE Version)
550 mm x 780 mm x ca. 1056 mm (20HE Version)
550 mm x 780 mm x ca. 1234mm (25HE Version)
Distance to Front and Rear
Min. 50 cm
Distance to top and
underside
Min. 20cm (top), 5 cm (underside)
Weight
approx. 100 kg (12HE Version cooler version)
10.3 Environmental conditions
Ambient temperature
10 to 40°C
Ambient humidity
50 % at 40°C or 80 % at 32°C
Max. Outlet temperature
60°C
Environment
Dry environment, indoor
Pollution degree 2
normally only non-conductive Pollution ocurrs