O
N
1
2
3
4
5
6
7
8
9 10
G-3 Except 65,000
ELECTRICAL DATA FOR THE USE OF CERTIFIED LICENSED ELECTRICIAN
WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone
Other Than A Certified Licensed Electrician!
All wiring MUST be in accordance with the National Electrical Code and all local codes.
G-2.5 & G-3 SERIES DIP SWITCH CONFIGURATION
1
Test Mode (normally off)
2
In “ON” position, Wide (custom) Serial Standard Panel
In “OFF” position, Generic Serial Standard Panel
3
N/A
4
Aux Freeze (must be OFF)
5
In “ON” position, Two-speed pump 1 when in Circ Mode (A9 On)
In “OFF” position, One-Speed pump 1 when in Circ Mode (A9 On)
6
In “ON” position, 50Hz operation
In “OFF” position, 60Hz operation
7
In “ON” position, Blower is enabled
In “OFF” position, Blower is disabled
8
In “ON” position, temperature is displayed in degrees Celsius
In “OFF” position, temperature is displayed in degrees Fahrenheit
9
In “ON” position, 24 Hour Circ Pump
Optional External Relay Board will allow 3
°
shutoff for Circ Pump
In “OFF” position, no Circ Pump
10
In “ON” position, 30A service
In “OFF” position, 50A service
DIP SWITCH KEY
A grounding lug has been provided on the exterior of the pack chassis to allow connection of a ground wire to a local
grounding point to be establish in compliance with the National Electric Code (NEC) and all local codes.
11
O
N
1
2
3
4
5
6
7
8
9 10
O
N
1
2
3
4
5
6
7
8
9 10
G-2.5 Only
G-3 65,000 Only
Summary of Contents for Genius G-2.5
Page 22: ...000798 10 04...