6800/7000 Series - Audio and Video Multi/Demultiplexing Products Installation and Operation Manual
93
Parameter Groups
Chapter 7: DEC-6804 Decoder and DES-6804 Decoder with Frame Synchronizer
Common Parameter Groups A and B (NTSC and PAL-B)
Parameter groups A and B are common to both NTSC and PAL-B
decoders.
Common Parameter Group A
SW1
Position
Function
SW3 Down
SW3 Up
Default Value
0
Group Select
Group Decrease
Group Increase
Group A
1
Standard
Force
Auto
Auto
2
Force Standard
625
525
525
3
Decode mode
Force
Auto
Auto
4
Force mode
Notch Filter
2-D Adaptive Filter
2-D
5
Genlock
(DES-6804 only)
Free Run
Sync mode
Sync mode
6
Sync mode
(DES-6804 only;
activated by
Sync
mode option in
Genlock
)
Delay mode
Synchronizing
mode
Synchronizing
mode
7
Analog Video Level
Decrease
Increase
Factory Settings
8
Analog Black Level
Decrease
Increase
9
Proc Luma Level
Decrease
Increase
A
Proc Chroma Level
Decrease
Increase
B
Proc Hue Phase
[wraps] (NTSC only)
Decrease
Increase
C
Proc Cb Offset
Decrease
Increase
D
Proc Cr Offset
Decrease
Increase
E
(Not functional)
F
Factory Recall
Recall
Recall
All default values in
parameter groups A,
B, C, and D.