Chapter 9: MXA-6800-AES and MXA-6801-A2/A4 Video/Audio Multiplexer Module
Control Parameter Details
152
6800/7000 Series - Audio and Video Multi/Demultiplexing Products Installation and Operation Manual
Operator Mode 3
The following table describes the
Operator Mode 3
with switch positions
0
to
2
,
3
to
E
and
F
:
Operator
Mode
Switch
Position
Result
3
0
No adjustment
• When the Hex switch is in this position, no
parameters can be altered and three dashes (“- - -”) will be
displayed in the Hex display.
3
1
Operator mode
• Can be changed to OS1, OS2, OS3.
3
2
AES Data Format
• Set On when the AES input is non-audio data in AES format.
• The default is Off (audio data).
(Not applicable in the MXA-6801-A2/A4)
3
3 to E
Reserved
• These switch positions are reserved in this mode, and the Hex
display will show three dots (“. . .”).
3
F
Factory Recall
• On or Off. When On, the factory settings are recalled.
The default is Off.