6800/7000 Series - Audio and Video Multi/Demultiplexing Products Installation and Operation Manual
153
Control Parameter Details
Chapter 9: MXA-6800-AES and MXA-6801-A2/A4 Video/Audio Multiplexer Module
Audio Error Messages
The following table describes the Audio Error messages. Error messages
are
not
applicable to the MXA-6800-A2/A4:
Audio
Error
Number
Error
Name
Error Condition
0
No Error
No errors
1
AES Input
#1 receiver
error
An AES input receiver error has occurred (crc, slipped sample).
2
AES Input
#2 receiver
error
An AES input receiver error has occurred (crc, slipped sample).
3
Embed
Error #1
Unintentional overwrite of auxiliary data.
See
“Audio Error Numbers” on page 155 for further information.
4
Embed
Error #2
Internal Audio FIFO over/underflow of auxiliary data:
• Asynchronism of audio to video clocks
• Incompatible sample distribution table
• RX_FIFO line is set too close.
See
“Audio Error Numbers” on page 155 for further information.
5
Embed
Error #3
Expected audio group is missing or in conflict with selected
group.
See
“Audio Error Numbers” on page 155 for further
information.
6
Embed
Error #4
Invalid embedding mode or missing internal video signal.
See
“Audio Error Numbers” on page 155 for further information.
7
Embed
Error #5
Embedding error caused by embedding mode selected and/or
embedded audio group missing on video input.
See “Audio Error Numbers” on page 155 for further information.