Chapter 1: ADC-6801 CAV to SDI Converter Module
Setup and Control
10
6800/7000 Series - Audio and Video Multi/Demultiplexing Products Installation and Operation Manual
Jumpers
Use jumper
J8
to terminates the external sync input with 75
Ω,
or leave it
at a high impedance (HI-Z) state for use during external loop through of
the sync input.
Jumpers
J5
and
J7
are for factory use only during board calibration and
should be in the
OP
position for correct board operation.
C
Internal
Color Bars
Enables the internally
generated color bars
signal.
The bars are 100% luma
and 75% chroma,100/0/
75/0.
UP
DN
Enabled
Disabled
D
Vertical
Blanking
Varies the blanking
width up to line 19 in
525 and line 22 in 625
standard.
UP
DN
Increase
Gain
Decrease
Gain
E
Factory
Recall
Recalls the factory auto
calibrated levels for the
given input. This recall
resets all of the user
offsets to zero and
restores the factory
Luma and Horizontal
phases.
See “
Factory
Recall Standards” on
page 11for further
information, it shows
the various levels as
specified for each
standard. Each refers to
100% color bar levels,
100/0/100/0 or 100/7.5/
100/0 with setup.
UP
DN
Recall
Recall
F
Reserved
SW1
Position
Function
Purpose
SW2
Position
SW2
Actions
Internal color bars are not rate
limited, so should not be used
“on-air”, as they are intended as
an alignment aid only.