Chapter 1: ADC-6801 CAV to SDI Converter Module
Setup and Control
12
6800/7000 Series - Audio and Video Multi/Demultiplexing Products Installation and Operation Manual
525, YPbPr,
with No Setup
Y
B-Y
R-Y
SMPTE
700 mV
700 mV
700 mV
**BETA
714 mV
1008 mV
1008 mV
MII
700 mV
648 mV
648 mV
NTSC
Invalid
525, YPbPr,
with Setup
Y
B-Y
R-Y
SMPTE
Invalid
*BETA
714 mVp-p
660 mV, 54 mVsetup
934 mV
934 mV
MII
700 mVp-p
648 mV, 52 mVsetup
648 mV
648 mV
NTSC
Invalid
525, GBR,
with No Setup
G
B
R
SMPTE
700 mV
700 mV
700 mV
*BETA
Invalid
MII
700 mV
700 mV
700 mV
NTSC
714 mV
714 mV
714 mV
525, GBR,
with Setup
G
B
R
SMPTE
Invalid
*BETA
Invalid
MII-related
700 mVp-p
648 mV, 52 mVsetup
700 mVp-p
648 mV, 52
mV setup
700 mVp-p
648 mV, 52
mVsetup
Illegal standards can be
selected, indicated by flashing
Activity
LED. In this situation,
the system software will choose
the closest standard and operate
from that standard. User offsets
to illegal standards are
permitted, but they are not
stored.
See
“Standard Select
Function” on page 11 for a list of
calibrated standard settings.
*Old, non-SMPTE/EBU
BETACAM levels.
** Used in Japan.