Chapter 2: ADC-6880 Analog to AES/EBU Digital Audio Converter
Configuration
20
6800/7000 Series - Audio and Video Multi/Demultiplexing Products Installation and Operation Manual
.
Figure 2-2.
Attenuation Jumper Settings
ADC-6880
Jumpers
Level
J1 & J12
J2 & J13
J3 & J14
J4 & J15
J6 & J17
J5 & J16
J7 & J18
J8 & J19
16 dBu
18 dBu
20 dBu
22 dBu
26 dBu
24 dBu
28 dBu
30 dBu
To set the required level, apply jumpers
to the proper set of jumper prongs.
This example shows that 28 dBu is selected.