5.4006.8501.0
B
4-27
4.3.4.6
Beep Length
This menu is used to set the duration of the beep. The default length is 200 mSec. This setting is for all
routes. When the value is set to zero, the beep is switched OFF.
4.3.4.7
Reset Report
This menu resets the service information data.
4.3.4.8
Fill Water
The menu
Fill water
is used to:
Set the
Push Power Fill
(default 15.5 A). The power the machine exerts on the water filling station must
be high enough to open the water valve without causing damage.
Set the
Pumpcurrent
(default 1000 mA). The pump must stop when the water tank is empty. When the
pump current drops below the set value, the pump stops.
Set the water fill function (
Water in use
) On or Off. When this setting is off, the machine does not stop at
the water filling station when it starts a route. This setting can be used to clean the barn without the use
of water, for example during periods of frost. When the setting is off, the machine skips a visit to the
water filling station and continues the route immediately.
4.3.5
Alarms
The machine monitors itself continuously and informs you about the situation. The machine generates
alarms and reports.
Alarm list
The alarm list gives a summary of the alarms received. This list stores up to 250 alarms. Once 250 alarms
are stored, the next alarm overwrites the oldest alarm of the list (see Alarm List on page 8-3).
Report list
The report list gives a summary of the generated reports (see Report List on page 8-11).
Info list
The list gives technical details. It is used by the service technician (see Information Report List on page 8-
13).
Reset list
To delete all alarm, report and info information.
4.3.6
Service
The menu
Service
has the following sub menus:
•
Hour counter
to display the hours in use since the last counter reset.
•
Version
to display the software version.
•
Installation 1
(password protected).
•
Installation 2
(password protected).
in n o vato rs in ag ric u ltu re
Summary of Contents for Lely Discovery 90 SW
Page 2: ...INTENTIONALLY BLANK 5 4006 8501 0 B innovators in agriculture ...
Page 6: ...INTENTIONALLY BLANK 5 4006 8501 0 B 6 List of Included Amendments innovators in agriculture ...
Page 16: ...INTENTIONALLY BLANK 5 4006 8501 0 B 1 2 Lely Discovery innovators in agriculture ...
Page 62: ...INTENTIONALLY BLANK 5 4006 8501 0 B 4 36 Description and Operation innovators in agriculture ...
Page 98: ...INTENTIONALLY BLANK 5 4006 8501 0 B 5 36 Operating Instructions innovators in agriculture ...
Page 124: ...INTENTIONALLY BLANK 5 4006 8501 0 B 7 8 Test and Adjustment innovators in agriculture ...
Page 146: ...INTENTIONALLY BLANK 5 4006 8501 0 B 9 2 Disposal innovators in agriculture ...
Page 149: ......