background image

Standard Connections Schematic

1  Connect an earth wire to grounding clamp 
2 Connect the TV aerial(s) to the amplifier’s inputs
3   Connect the MATV output and terminate the unused inputs with 75

Ω

 

loads

4   Connect the power supplier unit to the 

DSP35-4G

 and then connect the 

power supplier to mains plug

Installation and start-up

Lte790/4G

SAW Filters

UHF

BIII

DAB

UHF

UHF

Switching

Power Supplier

YS25-1501250

MATV Output
Test - 30dB

FM Input

USB Port

Summary of Contents for DSP35-4G

Page 1: ...NCY RANGE MHz FM 40 108 BIII 170 230 DAB 170 240 UHF 470 790 LTE PROTECTION LTE790 SINGLE CHANNEL FILTERS 32 NUMBER OF CHANNEL PER FILTERS 1 2 INPUT LEVEL RANGE dB V FM 35 90 BIII DAB 40 110 UHF 45 10...

Page 2: ...rocesses CAUTION To avoid the risk of electric shock do not open the equipment LEM GUI AUTO TUNING High rejection SAW filters for optimal protection against Lte 4G interferences In addition to the eas...

Page 3: ...P55 rating and fix it safely using the provided fixing plugs 4 Connect the power adapter cord to a detachable power supply socket Safety instructions IMPORTANT Use only the power supplier YS25 1501250...

Page 4: ...uts 3 Connect the MATV output and terminate the unused inputs with 75 loads 4 Connect the power supplier unit to the DSP35 4G and then connect the power supplier to mains plug Installation and start u...

Page 5: ...loads 4 Connect the power supplier unit to the coaxial DC injector INS02 and then connect the power supplier to mains plug DC Coaxial Injector not included Installation and start up UHF BIII DAB UHF...

Page 6: ...g menu OUTPUT LEV 110dBuV Confirmation Key Menu browsing keys Display LDC 2 x 12 Pointer to scroll figures Function Selector Note the display will go out after 3 minutes if inactive but the menu will...

Page 7: ...ING procedure press for 5 seconds To begin the AUTO TUNING procedure connect the antenna s to the DSP35 4G inputs then follow the operations described below The amplifier DSP35 4G will start scanning...

Page 8: ...to enter the menu INPUT 1 VHF INPUT 1 VHF Processable channels Input E5 E13 DAB Output E5 69 Press the keys at the same time to go back to the main menu from anywhere in the INPUT menu PREAMP OFF DC O...

Page 9: ...eys then press twice to confirm 5 5 L 65 PREAMP ON To activate the filtering and conversion function on a single MUX set the desired input channel through the keys and press to confirm Select the outp...

Page 10: ...To adjust the UHF slope select SLP and press press to select the required value and press to confirm UHF SLOPE Adjustablefrom0to5dB SLP 5dB VHF 10dB To adjust the VHF gain select VHF and press press t...

Page 11: ...t THR the AUTO TUNING and MONITOR miminum threshold function and press Use the keys to select the required value and press to confirm REMOTE POWER SUPPLY PROTECTION PASSCODE AUTO TUNING INPUTS THRESHO...

Page 12: ...mode and press to confirm To carry on with the programming select NO and press to confirm THR 55dBuV RESET MONITOR RESET MONIT OFF The MONITOR function activates a real time monitoring procedure whic...

Page 13: ...lease check the power supplier DC NOT VALID Display Error Messages OVERCURRENT Input short circuit or over current Please check the input s with the remote power supply activated and remove the issue...

Page 14: ...DSP35 4G Label with serial and tracking data Model Serial Manuf Week Manuf Year HW Rel FW Rel 1 DownloadthelatestGUIreleasefromourwebsitehttp www lemelettronica it 2 Install the GUI selecting the file...

Page 15: ...LEM ELETTRONICA srl Via Grezze 38 25015 Desenzano d G Italy Tel 39 0309120006 Fax 39 0309123035 info lemelettronica it www lemelettronica it...

Page 16: ...EQUENCY RANGE MHz FM 40 108 BIII 170 230 DAB 170 240 UHF 470 694 LTE PROTECTION LTE700 SINGLE CHANNEL FILTERS 32 NUMBER OF CHANNEL PER FILTERS 1 2 INPUT LEVEL RANGE dB V FM 35 90 BIII DAB 40 110 UHF 4...

Page 17: ...sses CAUTION To avoid the risk of electric shock do not open the equipment LEM GUI AUTO TUNING High rejection SAW filters for optimal protection against Lte 4G and 5G interferences In addition to the...

Page 18: ...P55 rating and fix it safely using the provided fixing plugs 4 Connect the power adapter cord to a detachable power supply socket Safety instructions IMPORTANT Use only the power supplier YS25 1501250...

Page 19: ...uts 3 Connect the MATV output and terminate the unused inputs with 75 loads 4 Connect the power supplier unit to the DSP35 5G and then connect the power supplier to mains plug Installation and start u...

Page 20: ...loads 4 Connect the power supplier unit to the coaxial DC injector INS02 and then connect the power supplier to mains plug DC Coaxial Injector not included Installation and start up UHF BIII DAB UHF...

Page 21: ...g menu OUTPUT LEV 110dBuV Confirmation Key Menu browsing keys Display LDC 2 x 12 Pointer to scroll figures Function Selector Note the display will go out after 3 minutes if inactive but the menu will...

Page 22: ...ING procedure press for 5 seconds To begin the AUTO TUNING procedure connect the antenna s to the DSP35 5G inputs then follow the operations described below The amplifier DSP35 5G will start scanning...

Page 23: ...to enter the menu INPUT 1 VHF INPUT 1 VHF Processable channels Input E5 E13 DAB Output E5 69 Press the keys at the same time to go back to the main menu from anywhere in the INPUT menu PREAMP OFF DC O...

Page 24: ...eys then press twice to confirm 5 5 L 65 PREAMP ON To activate the filtering and conversion function on a single MUX set the desired input channel through the keys and press to confirm Select the outp...

Page 25: ...To adjust the UHF slope select SLP and press press to select the required value and press to confirm UHF SLOPE Adjustablefrom0to5dB SLP 5dB VHF 10dB To adjust the VHF gain select VHF and press press t...

Page 26: ...t THR the AUTO TUNING and MONITOR miminum threshold function and press Use the keys to select the required value and press to confirm REMOTE POWER SUPPLY PROTECTION PASSCODE AUTO TUNING INPUTS THRESHO...

Page 27: ...mode and press to confirm To carry on with the programming select NO and press to confirm THR 55dBuV RESET MONITOR RESET MONIT OFF The MONITOR function activates a real time monitoring procedure whic...

Page 28: ...lease check the power supplier DC NOT VALID Display Error Messages OVERCURRENT Input short circuit or over current Please check the input s with the remote power supply activated and remove the issue...

Page 29: ...DSP35 5G Label with serial and tracking data Model Serial Manuf Week Manuf Year HW Rel FW Rel 1 DownloadthelatestGUIreleasefromourwebsitehttp www lemelettronica it 2 Install the GUI selecting the file...

Page 30: ...LEM ELETTRONICA srl Via Grezze 38 25015 Desenzano d G Italy Tel 39 0309120006 Fax 39 0309123035 info lemelettronica it www lemelettronica it...