EN
heavy impact, or been dropped, damaged, left out in the open
or fallen into water, do not use it until it has been checked out;
contact a specialist technician approved by IP Cleaning or take
the machine to any IP Cleaning service centre.
•
Battery charger: inspect the battery charge cable periodically
for possible damage. If damage has occurred, do not use the
battery charger until the cable has been replaced; contact a
specialist technician approved by IP Cleaning or take the
machine to any IP Cleaning service centre.
•
Make certain the power sockets used for mains powered models
and battery chargers are properly earthed and protected by a
2-pole thermal magnetic switch with differential circuit-breaker:
•
rated current 10-16A
•
IΔn differential current: 0.03A
•
Icn breaking capacity: 6000 A
•
AC differential breaker trip
•
This machine (mains powered model) must be earthed. In the
event of a malfunction or failure, the earth connection provides
the path of least resistance for electrical current, reducing
the risk of electric shock. Mains powered versions come with
a three-core cable and a three-pin plug for connection to a
suitable earthed power socket. The earth wire is yellow and
green. Never connect this wire to anything other than the earth
terminal of the socket. The plug must be inserted into a suitable
socket, correctly installed and wired in accordance with local
building regulations. Incorrect wiring or failure to connect the
earth wire of the machine may lead to the risk of electric shock.
If in doubt about the proper earthing of the power socket, have
it checked by a qualified electrician. Do not tamper with the
plug fitted to the machine, and use only sockets compatible
with this same plug. If the power socket needs to be replaced,
have the job done by a professional electrician.
•
Do not clean the machine with water or a high pressure hose.
4