3.8.3
Pump Tubing
500ft (~150m) of Uponor plastic Pump Tubing
Figure 3-30 - Pump Tubing
3.9
Pump Float Switch
The Pump Float Switch can be used to automate the pumping system. The Pump Float Switch is mounted inside of a
tank which is to be filled by water from the Pump Float. When the tank fills above the fixed height of the Pump Float
Switch, the Pump Float Switch will flip upright as it floats in the tank water. This trips an electrical circuit which the
controls system monitors. Then the Pump Float Switch indicates the tank is full, the pump turns off.
Figure 3-31 - Pump Float Switch