Peak Detection mechanism
As shown in Figure No 8 there is a colored indicator of the peak detection mechanism, for each output transport
stream. This indicates if any overflow has occurred on modulator’s output bitrate with the following colors:
•
Green
– No overflow occurred
•
Yellow
– No overflow occurred but the input bitrate is close to the output bitrate
•
Red
– Overflow occurred. The user must decrease the input bitrate
4.2.7 - “IP streaming” page
At “IP streaming” section the user is able to setup the IP streamer of the device (Figure No 10).
In Figure No 10 we have general settings of the IP streamer as follows:
•
IP address: This is the IP address of the streamer for ping purposes.
•
MAC address: This is the MAC address of the streamer
•
Figure No 10