Installation manual
– English
Base frame
(Foundation joists)
The base frame of the house must be completely flat and level to ensure that the installation proceeds
without problems.
ATTENTION: different house can have different foundation placements
– see the appended
base frame drawing (in Technical specifications)!
Place the impregnated foundation joists on the prepared foundation in accordance with the drawing at
equal intervals. Make sure that the joists are level and rectangular prior to screwing them together.
ADVICE
: It is recommended to place between the foundation joists and foundation a damp-proof
course that will protect the house from moisture and decay.
ADVICE
: To ensure protection from wind and storm, it is recommended to attach the foundation joists
to the foundation (for this, you can use for instance metal angles, anchors, etc.). The corresponding
materials are not included in the supplied kit!
Installation of foundation joists:
Walls
When installing the walls, it is important to remember that:
➢
The logs are always assembled with their tongue upwards!
➢
If necessary, use the hitting block and hammer! Never directly hit the tongue with the hammer!
Install the walls in accordance with the appended wall plans (see Technical specifications).
First of all place half logs of front and back wall at the
correct location and attach them with screws to the
foundation joists. Then install the side wall logs. Make sure
that the first layer of logs extends a bit over the foundation
joists: the logs must extend over the joists by some 3-5 mm.
You will thus protect the house from moisture, allowing the
free flow of rainwater into the ground.
ATTENTION
:
After the first layer of logs, measure the
diagonal lengths and, if necessary, re-install the logs. Only if
the diagonal lengths are completely equal is the base frame
rectangular and you can mutually attach the logs.
The first layer of logs:
Summary of Contents for 109159
Page 5: ......
Page 6: ...BOX ...
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ...Ø3 1 SP2 5x80 RoR1 Ø3 1 A A B 6x180 RoR1 5x90 5x90 5x80 RoR2 SP2 6x150 B SP1 SP2 SP2 SP2 2180 ...
Page 16: ...RE2 x RB2 x SP2 4 5x50 RE2 2 RE2 3 RE2 1 C C ca 25 ca 1 RB2 2 RB2 1 ...
Page 18: ...RE2 x RB2 x SP2 Rai7 Rai8 Rai7 Rai8 Rai7 Rai8 4 5x50 E E ...
Page 19: ...19x114 19x114 RE2 x RB2 x SP2 underlayer is recommended SBS SBS SBS ca 200 SBS ...
Page 20: ...SBS SBS SBS CoB CoB 4 5x50 SBS underlayer is recommende ...
Page 21: ...GLUE 19x114 19x114 RE2 x RB2 x SP1 EPDM EPDM ...