background image

3

SAFETY PRECAUTIONS

WARNING

1)

Injection hazard:  Airless Painting Equipment can
cause serious injury if the spray penetrates the
skin.  Do not point the gun at anyone or any part of
the body. The tip guard provides some protection
against accidental injection injuries, but is mostly a
warning device. Never put your hand, fingers or
body over the spray tip. Gloves and clothing do not
necessarily offer any protection either. Keep the
gun trigger safety lever in locked postion when not
spraying. Always have the tip guard in place while
spraying.
In case of penetration seek medical aid immediately!
Note to physician: Injection into skin is a serious
traumatic injury. It is important to treat the injury
surgically as soon as possible. Do not delay treat-
ment to research toxicity. Toxicity is a concern with
some exotic coatings injected into the bloodstream.
Consultation with a plastic surgeon or reconstructive
hand surgeon may be advisable. Be prepared to tell
the doctor what fluid was injected.

2)

This system is capable of producing 3200 PSI.  To
avoid rupture and injury, do not operate this pump with
components rated less than 3200 PSI working pressure
(including but not limited to spray guns, hose and hose
connections).

3)

Do not spray paints or other inflammable fluids
indoors 
which have a flash point below 21 degree C, 70
degree F.  Keep spray area well ventilated.  Before
spraying, turn off all pilot lights and open flames.

4)

Wear a respirator which is approved for the product
being sprayed.

5)

Do not use halogenated hydrocarbon solvents in this
system; it contains aluminium parts and may explode.
Cleaning agents, coatings, paints, and adhesives may
contain halogenated hydrocarbon solvents. Don't take
chances, consult your material supplier to be sure. (ex:
methylene chloride and 1,1,1 - Trichlorethane)

6)

Caution: When a flammable liquid is sprayed there may
be danger of fire or explosion especially in a closed
area.

7)

Caution: Arcing parts. Keep the pump at least 20 feet
away from explosive vapors.

8)

Caution: Static electricity can be developed by airless
spraying. Ground unit and object to be sprayed. On
electric units, unit power cord must be connected to a
grounded outlet. Use only three wire extension cords.
Static explosion can occur with ungrounded unit.

9)

Flush system with spray tip removed. Always use
lowest pressure possible.

10) Always follow safety precautions and warnings printed

on paint container.

11) Only use spray guns and hoses supplied by Lemmer.

User assumes all risk and liability when using spray guns
or hoses not complying with minimum specification and
safety devices of Lemmer Spray Systems Ltd.

12) Inspect hoses before each use. Never use a damaged

hose. High pressure in hoses with wear, leaks or splits
may cause the hose to rupture and cause serious
personal injury. Never try to stop or deflect leaks with any
part of your body.

13) Use extreme caution when cleaning spray tip guard.

DO NOT try to wipe off build up around the spray tip
before following shut down procedure. Follow the Shut
down Procedure, then follow the spray tip manufacturer’s
instructions for removing and cleaning the spray tip.

14) Never attempt to change spray tip or leave the unit

unattended without first shutting off pump, releasing fluid
pressure, and locking the trigger safety lock.

15) Use extreme caution when changing spray tip. Follow

the Shut down Procedure, then follow the spray tip
manufacturer’s instructions for changing the spray tip.

ATTENTION

1)

Risque d’injection de peinture:  Le matériel de

pulvérisation sans air peut entraîner de graves blessures
s’il y a pénétration de la peau par la peinture.  Ne jamais
pointer le pistolet vers une personne ou vers soi-même.
La garde de la buse limite le risque de blessures
accidentelles par injection mais constitue principalement
un élément de mise-en-garde. Ne jamais mettre la main,
les doigts ou toutes parties du corps contre la buse. Le
port de gants et de vêtements n'est pas nécessairement
une forme de protection non plus.Laisser le cran de sureté
du pistolet en position fermée quand il nést pas utilisé.

Toujours avoir la garde en place pour peindre.
En cas d’accident, demander immédiatement des soins médicaux.
Note au médicin: La pénétration de peinture dans la peau peut causer
de graves blessures. Il est important de traîter la blessure à la
chirurgie aussitôt possible. Ne pas retarder le traitement pour
rechercher la toxicité. La toxicité peut avoir de graves conséquences
quand certains enduits exotiques son injectés directement dans le
systéme sanguin. Une consultation avec un chirurgien spécialisant en
reconstruction de mains serait conseillable. Soyez prêts à décrire au
médecin quel liquide a été injecté.

2)

Ce matériel peut produire une pression de 3200 lbf/po2.  Afin d’éviter
des ruptures et des blessures, ne pas utiliser cette pompe avec des
éléments dont la pression nominale de service est inférieure à 3200 lbf/po2
(y compris les pulvérisateurs, tuyaux flexibles et raccords).

3)

Ne jamaipulvériser à l’interieur un produit inflammable qui a un point
éclair inférieur à 21 degrés C,70 degrés F.  L’endroit où vous peinturez doit
toujours être bien aéré.  Avant de pulvériser s’assurer qu’il n’y a aucune
flamme ou pilot (veilleuse) de fournaise en marche dans l’appartement.

4)

Servez-vous d’un masque respiratoire qui est certifié pour le produit que
vous pulvérisez.

5)

Ne pas utiliser de solvants contenant des hydrocarbures halogénés
avec ce matériel. Il contient des particules d'aluminium et peut exploser. Les
agents de nettoyage, enduits, peintures et, adhésifs, peuvent contenir des
solvants contenant des hydrocarbures halogénés. Soyez prudents;
consultez votre fournisseur pour les informations nécessaires. (ex:
méthylène chloride and 1,1,1 - Trichloréthane)

6)

Attention: La pulvérisaton d'un liquide inflammable peut entraîner un
risque d'incendie ou d'explosion, surtout dans les espaces fermés.

7)

Attention: Étincelles électriques. Ne pas placer la pompe à moins de 6
mètres des vapeurs explosives.

8)

Attention: La pression du produit que l’on pulvérise peut produire une
charge électrostatique.  Mettre le matériel et l'objet à pulvériser à la terre.
Sur les modèles électriques, le cordon électrique doit être attaché à une
prise de courrant reliée à terre. Le cordon de rallonge doit être à 3 fils. Des
décharges d'électricité statique peuvent se produire si le matériel n'est pas
mis à la terre.

9)

Retirer l'embout de pulvérisation avant de rincer le matériel tout en
utilisant une pression aussi basse que possible.

10) Toujours prendre les précautions nécessaires et observer toutes les

consignes de sécurité figurant sur le pot de peinture.

11) N'utiliser que les pulvérisateurs et les tuyaux flexibles fournis par

Lemmer. Les personnes qui utilisent des pulvérisateurs et des tuyaux
flexibles non conformes aux standards d'utilisation et de sécurité minimum
du fabricant de la pompe le font à leurs propres risques et seront les seuls
responsables.

12) Examiner soigneusement le tuyau avant de s'en servir. Il ne faut jamais

utiliser un tuyau endommagé ou avec des fentes. Un tuyau à haute pression
qui n'est pas en bon état représente un serieux danger de blessure à la
personne en cas de crevaison soudaine. Il ne faut jamais essayer d'arrêter
des fuites de liquide avec n'importe quelle partie de votre corps.

13) Il est nécessaire d'exercer beaucoup de précaution pendant le

nettoyage de la protection de la buse. Ne jamais essayer d'enlever la
peinture qui aurait pu s'accumuler sur la buse avant d'avoir suivi les
consignes de sécurité concernant le nettoyage et le remplacement de la
buse.

14) Ne jamais essayer de changer la buse ou laisser l'appareil sans surveillance

avant d'arrêter le moteur, couper la pression et verrouiller la gâchette du
pistolet.

15) Le remplacement d'une buse doit être fait avec beaucoup de

précaution. Référez-vous au PROCÉDÉ D'ENTRETIEN.

HIGH PRESSURE!

INJECTION HAZARD!

Summary of Contents for DC-3000

Page 1: ...materials sprayer must be placed at least 20 feet from target in a well ventilated area Vapours can be ignited by static discharge or electrical sparks and result in severe personal injury LEMMER airl...

Page 2: ...HINTS FOR AIRLESS SPRAYING PAINTING AND TIP SELECTION 12 SPRAY PAINTING METHOD 12 HELPFUL HINTS FOR TROUBLE FREE PAINTING SPRAYER 12 PAINT 12 SPRAY TIPS 12 FILTERS 12 PAINT HOSE 12 ELECTRICAL 13 EXTEN...

Page 3: ...garde Ne jamais mettre la main les doigts ou toutes parties du corps contre la buse Le port de gants et de v tements n est pas n cessairement une forme de protection non plus Laisser le cran de suret...

Page 4: ...to move equipment DO NOT kink or bend the hose sharply 17 Keep children or anyone not familiar with airless spray systems away from equipment and work area 18 Conductive metal containers must be used...

Page 5: ...tor operates only as fast as the job requires again reducing wear DC 4000 only Accurate spray pattern with minimal overspray Minimal or no thinning of paint products Pumps straight out of original pai...

Page 6: ...ds depending on how much voltage it is sent by pressure control box This allows for highly accurate control of pressure Motor also features long life brushes which are readily accessible from the outs...

Page 7: ...t ELECTRONIC CONTROLS DC 4000 OFF The first 10 20 degrees of pressure knob rotation do not activate unit PRIME ZONE The next approx 20 degrees of rotation will turn the motor on at a constant slow spe...

Page 8: ...94 029 8 40 DEG 3 1 429 L043 295 029 10 50 DEG 3 1 529 L043 296 029 12 60 DEG 3 1 629 L043 297 029 14 70 DEG 3 1 729 L043 298 029 16 80 DEG 3 1 829 L043 299 029 18 90 DEG 3 1 929 L043 313 031 6 30 DEG...

Page 9: ...protect against accidental injection and prevents tip from slipping out of position Patented Diffuser safer unclogging in clean out posi tion TO OPERATE When tip clogs turn zip tip handle 180 to clean...

Page 10: ...of fan width 8 1 foot 15 orifice size in thousands of an inch 015 Y Yellow 100 mesh filter R Red 180 mesh Y Yellow 100 mesh W White 50 mesh not recommended Tip volume at various pressures Gallons per...

Page 11: ...up pressure about 1 6 turn This gives a good low pressure for flushing and cleaning 8 Aim gun into empty metal pail holding gun body against pail edge to ground gun for safety Open trigger and allow...

Page 12: ...at gives an adequate spray pattern is the best pressure to use It will give maximum pump and tip life and produce minimum overspray 2 Typically thicker materials require larger tips and higher pressur...

Page 13: ...the gun first HELPFUL HINTS FOR TROUBLE FREE PAINTING PAINT HOSE 1 INSPECT THE HOSE PERIODICALLY DO NOT USE KINKED WORN OR DAMAGED HOSE SEE WARNINGS ON PAGES 3 4 2 Use only hose that is designed for...

Page 14: ...n causes of problems If followed these guidelines will insure trouble free performance from your sprayer CAUTION Clean with water if latex is used Clean with paint thinners for oil based paints Both w...

Page 15: ...gun filter Remove filter and brush clean with appropriate solvent Inspect filter for pinholes plugging or other damage Replace if required Re install with double lip end pointing up into gun Lightly...

Page 16: ...ld brushes put back on same side of motor same way up as before to reduce break in time 6 Install brush caps DO NOT OVERTIGHTEN AS BRUSH CAPS ARE BAKELITE AND WILL BREAK 7 Put unit in solvent open pri...

Page 17: ...Push the packings out of the cylinder with a screw driver by pushing from the inside out push from the opposite end INSTALLING NEW PUMP PACKINGS 9 Apply a light coat of oil to the packings Install bot...

Page 18: ...the fluid section into the main pump housing Rotate the fluid pump to align the hole in the piston shaft with the holes in the yoke 25 Insert the pin through the yoke and piston Snap the retaining cl...

Page 19: ...disconnect Disconnect the two from the power cord the lower pair first These go to the switch 6 The second pair of wires go the the bridge rectifier from the motor upper pair Disconnect these 7 Contr...

Page 20: ...and footvalve seats for wear 20 Place new upper packings in oil L034 125 to soak for 5 10 minutes 21 Put piston in vice using flats Install new ball and copper seal Use a little bit of grease to hold...

Page 21: ...Sprayer starts up but does not draw up paint III Sprayer will not maintain pressure or has low output IV Upper end of fluid section leaks V Poor spray pattern VI Spray gun won t shut off VII Spray ti...

Page 22: ...APHRAGM These sprayers are the same as the electric diaphragm pumps but with the advantage of a gas engine All use Honda motors and belt drive systems AUTOMATIC GUNS Suitable for all heavy duty airles...

Page 23: ...ls L034 222 Extra large overalls L034 223 1 Gal stir rod 2 3 8 dia 3 8 chuck L034 050 1 Gal stir rod 3 1 4 dia 3 8 chuck L034 051 5 Gal stir rod 4 3 4 dia 1 2 chuck L034 052 SPRAY HOODS Spray hoods pa...

Page 24: ...to change spray tip or leave the unit unattended without first shutting off pump releasing fluid pressure and locking the trigger safety lock Conductive metal containers must be used when flushing fl...

Page 25: ...ke spring 15 off of shaft for cleaning 10 If the ball 10 has a groove worn in it the ball with shaft will have to be replaced Usually the seat will have to be replaced as well as it wears against the...

Page 26: ...2 112 94 112 56 112 97 98 99 100 101 102 103 104 105 106 107 108 109 110 Do not remove unless replacing Important following items require accurate torques 62 transducer plug 20 ft lbs 91 packing nut 2...

Page 27: ...540 Screw 4 54 L045 541 Electric cord 1 55 L045 542 Strain relief 90 1 56 L036 001 Connector 1 4 m 2 57 L045 543 Fuse holder 1 58 L045 544 Fuse 10 amp 1 59 L050 617 18 connection hose 1 60 L036 091 El...

Page 28: ...packings female support poly leather poly leather poly male support lower packings male support poly poly poly poly female support Caution only use fibre braid high pressure airless hose Do Not use st...

Page 29: ...allen 5 42 L050 519 Oil seal 1 43 L050 526 Rod bearing 1 44 L050 532 Rod bushing 1 45 L050 530 Connecting rod incl Pos 44 1 46 L050 524 Cover screw M4 x 10 3 47 L050 523 Front cover 1 48 L050 537 Pai...

Page 30: ...poly poly poly poly female support male support 64 Only replace this seal if external leak is evident Once seal is removed it must be replaced 84 92 80 81 93 88 89 90 91 86 77 78 83 82 87 66 65 75 74...

Page 31: ...Strain relief 14 3 thick panel 1 35 L050 535 Drain plug 1 36 L001 555 Copper seal 3 40 L001 550 Washer knurled lock M10 5 41 L050 520 Housing bolt M10 x 1 5 x 16 allen 5 42 L050 519 Oil seal 1 43 L050...

Page 32: ...rtation costs and other incidental direct special or consequential damages or loss specifications are subject to change without notice May 00 caract ristiques sont sujets changement sans pr vis Mai 00...

Reviews: