background image

Tube Replacement

   

Shut down the power and remove the power cord before replacing the flash tube 

and wear insulated gloves. Then, loosen the iron wire on the tube, keep a balanced 

hold on the two feet of the flash tube and pull out the old tube gently. Take down the 

feet casing from the old tube and put it on the new one. Hold two feet of the new 

tube, and target directly towards the two copper outlets, then push them slightly in. 

Twine the iron wire on the stainless steel sheet to fix the flash tube.

The flash unit is built in with a Wireless Control Port so that you can 
wirelessly adjust the power level of the flash and the flash triggering. 
To control the flash wirelessly, you need a WaveSync

          remote control

on-camera and on-flash). Insert its receive end into the Wireless Control 
Port on the flash and insert the transmit end into the 
camera hot shoe. Settings made on the hotshoe-
mounted transmit and receive ends will be wirelessly 
communicated to the flash. Then you can press the 
camera shutter release  button to trigger the flash. You 
can also hold the transmit end at hand to control your 
off-camera flash.

For full instructions on the use of WaveSync and Godox triggers

please visit lencarta.com/downloads-manuals-reviews-lencarta

 

TECHNICAL DATA

MAINTENANCE

SmartFlash 4

300WS

Dimension

Net Weight

19 x 11 x 14cm (not including

reflector or modelling lamp)

Approx. 1.7KG

Shut down the device immediately when it works abnormally and find out the reason.
Avoid sudden impacts and the lamp should be dedusted regularly.
It is normal for the lamp to be warm when in use. Avoid continuous flashes if unnecessary.
Maintenance of the flash must be performed by our authorized maintenance department 
which can provide original accessories. The flash-tube and the modeling lamp are 
user-replaceable. Replacement tubes and lamps can be obtained from the manufacturer.
This product, except consumables e.g. flash tube and modeling lamp, is supported with 
a one-year warranty.
Unauthorized service will void the warranty.
If the product had failures or was wetted, do not use it until it is repaired by professionals.
Disconnect the power when cleaning the flash or when changing the flashtube / 
modeling lamp.
Changes made to the specifications or designs may not be reflected in this manual.

within 1s

58

5600±200K

 

AC220V-240V~50Hz

OFF, 5.0~10.0

(

1/32~1/1)

150W

Full Wired/Wireless

1/2000~1/800s

5V

5V/200mA

AC220V-240V~50Hz: 5A

Model

Max Power (WS)
Guide Number(m ISO 100)
Color Temperature
Operating Voltage
Power Output Control
Modeling Lamp (W)
Recycle Time
Triggering Method
Flash Duration
Parameters output from 
the sync cord jack 
Parameters output from  
the USB port
Fuse

Summary of Contents for SmartFlash 4

Page 1: ...Instruction Manual Unit 3a Mohair Mills Gibson Street Bradford BD3 9TR Tel 44 1274 678842 Email support lencarta com www lencarta com T Lencarta Ltd ...

Page 2: ... reach of children Please put the device in a ventilation environment and keep the parts of lighting and heat dissipation holes are unobstructed Do not use in flammable environment As this product adopts make and break device please keep it easy to be used No touching the heating parts of this product Please turn off the power and wear insulated gloves before installing and connecting accessories ...

Page 3: ...mpatible with the vast majority of light shapers on the market such as the Lencarta ProFold range and popular Folding Beauy Dishes 1 Built in 2 4G Wireless Transmission 2 Built in Wireless Channel 3 Built in Wireless Channel Dial 4 Slave Model Indicator 5 Beep 6 Temperature Alarm Display 7 Built in Wireless Group 8 Flash Output 9 Modeling Lamp is off 10 Modeling Lamp is in the PROP mode 11 Modelin...

Page 4: ...king Turn the Select Dial to choose the light brightness from 5 to 100 Short press the SET Button to exit Modeling Lamp When there is flammable accessory on the flash unit do not keep the modeling lamp on for a long time It is recommended to cool it down for one minute after 10 minutes working 3 When PROP is displayed short press the MOD OFF Button can back to OFF mode 4 When in NON OFF mode long ...

Page 5: ...ponse to the second actual flash from the main unit Buzz Function The BUZZ button 8 is used for deciding whether there is sound reminder for ready flash after recharging When the buzz indicator is on the LCD panel the buzz function is working when it is disappear the buzz function is not working A BI sound will be heard when it s fully charged Key Combination Synchronously press the GR CH Button a...

Page 6: ...iews lencarta TECHNICAL DATA MAINTENANCE SmartFlash 4 300WS Dimension Net Weight 19 x 11 x 14cm not including reflector or modelling lamp Approx 1 7KG Shut down the device immediately when it works abnormally and find out the reason Avoid sudden impacts and the lamp should be dedusted regularly It is normal for the lamp to be warm when in use Avoid continuous flashes if unnecessary Maintenance of ...

Reviews: