Tube Replacement
Shut down the power and remove the power cord before replacing the flash tube
and wear insulated gloves. Then, loosen the iron wire on the tube, keep a balanced
hold on the two feet of the flash tube and pull out the old tube gently. Take down the
feet casing from the old tube and put it on the new one. Hold two feet of the new
tube, and target directly towards the two copper outlets, then push them slightly in.
Twine the iron wire on the stainless steel sheet to fix the flash tube.
The flash unit is built in with a Wireless Control Port so that you can
wirelessly adjust the power level of the flash and the flash triggering.
To control the flash wirelessly, you need a WaveSync
remote control
on-camera and on-flash). Insert its receive end into the Wireless Control
Port on the flash and insert the transmit end into the
camera hot shoe. Settings made on the hotshoe-
mounted transmit and receive ends will be wirelessly
communicated to the flash. Then you can press the
camera shutter release button to trigger the flash. You
can also hold the transmit end at hand to control your
off-camera flash.
For full instructions on the use of WaveSync and Godox triggers
please visit lencarta.com/downloads-manuals-reviews-lencarta
TECHNICAL DATA
MAINTENANCE
SmartFlash 4
300WS
Dimension
Net Weight
19 x 11 x 14cm (not including
reflector or modelling lamp)
Approx. 1.7KG
Shut down the device immediately when it works abnormally and find out the reason.
Avoid sudden impacts and the lamp should be dedusted regularly.
It is normal for the lamp to be warm when in use. Avoid continuous flashes if unnecessary.
Maintenance of the flash must be performed by our authorized maintenance department
which can provide original accessories. The flash-tube and the modeling lamp are
user-replaceable. Replacement tubes and lamps can be obtained from the manufacturer.
This product, except consumables e.g. flash tube and modeling lamp, is supported with
a one-year warranty.
Unauthorized service will void the warranty.
If the product had failures or was wetted, do not use it until it is repaired by professionals.
Disconnect the power when cleaning the flash or when changing the flashtube /
modeling lamp.
Changes made to the specifications or designs may not be reflected in this manual.
within 1s
58
5600±200K
AC220V-240V~50Hz
OFF, 5.0~10.0
(
1/32~1/1)
150W
Full Wired/Wireless
1/2000~1/800s
5V
5V/200mA
AC220V-240V~50Hz: 5A
Model
Max Power (WS)
Guide Number(m ISO 100)
Color Temperature
Operating Voltage
Power Output Control
Modeling Lamp (W)
Recycle Time
Triggering Method
Flash Duration
Parameters output from
the sync cord jack
Parameters output from
the USB port
Fuse