Wiring
Power and Network connections:
1. Plug the unit into a standard 115VAC power outlet. The system will be usable in approximately 10 seconds.
Data, and Ground connections:
1.
Wire the Data in cable to the previous OP or head-end Data out. Wire the Data Out cable to the next OP’s Data
In.
On the last OP only, connect a data terminator to the OP's data out port
2.
Wire a ground wire from the GND connector to the previous and next OP ground or to the head
end common.
Audio Common (not building ground).
TO NEXT OP
DATA IN
TO OP “-“ OR HEAD-
END GROUND
IR connections:
:
1. Connect an IR unit to the IR port.
IR1 for U1 speakers.
IR2 for U2 speakers.
IR3 for U3 speakers.
IR4 for U4 speakers.
DATA IN
FROM HEAD-END
OR PREVIOUS OP
*Note: "U" refers to the unit number, not the OP number.
5