31
Flue Size
3” (76 mm) Rear
Floor Protection
Front: 6” (152mm)
Requirements
Sides: 3” (76mm)
Back: 0*”(0 mm)
u
Hopper Capacity
75 Lbs.
v
Burn time
15-1/2 to 42 hours
v
Fuse, Control Board
3 Amp, 250 volt, 3AG
w
Fuse, Igniter
6 Amp, 250 volt
w
Heat Input
15,300-43,000 BTU/hr
v
(BTU’s per hour)
Efficiency Rating
81%
Emissions
1.01 gr/hr, EPA Certified (method 28)
SPECIFICATIONS - Bella™
Convection (room air)
Blower
150 CFM; .90 Amps,
1650 rpm
Combustion Blower
100 CFM: 1.3 Amps,
3000 rpm
Auger Motor
1.28 RPM; .4 Amps
Standard Features
Self Igniter
Notes:
• Dimensions shown are approximations only
(+/- 1/4”)
• Approved for Manufactured Home Installations.
•
Optional kits available - Stone Panel Kits, Brick Panel Kits, Log Set, Leg Leveling
Kit, Remote Control and Wall Thermostat.
u
In Canada floor protection is required directly underneath and 2" from the sides
of the flue or chimney adapter. Recommended in the US.
v
Burn times, hopper capacity and BTU input may vary depending on the size
and type of fuel used.
w
Fuses are rated as fast acting.
Flue Outlet
Combustion
Air Inlet
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Product Reference Information
Cat. No.
Model
Description
Ship.
Weight
Ship.
Volume
H3480
BELLA-B
Bella, Black Cast
411 lb.
24 cu. ft.
H3481
BELLA-BE
Bella, Espresso
Brown
415 lb.
24 cu. ft.
7-1/4”
(184mm)
5-1/2”
(140mm)
34”
(864mm)
24-7/8” (632mm)
2-3/8”
(60mm)
6-9/16”
(167mm)
C/L
34”
(864mm)
24-7/8”
(632mm)
33-15/16”
(862mm)
20-1/2”
(521mm)
5-1/2” (144mm)
24-7/8”
(632mm)
25-9/16”
(649mm)
20-7/16”
(519mm)
Left Side View
Front View
Right Side View
Top View
Back View
Summary of Contents for BELLA