6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Parallel and Alcove Installations - Clearance to
Combustibles
Alcove Installations - Clearance to Combustibles
Minimum clearance from back of stove to back wall = 2 inches
Minimum clearance from sides of stove to wall = 5 inches
Minimum clearance from exhaust pipe to side wall = 8-11/16 inches
Minimum height of ceiling = 60 inches
Minimum alcove width = 33-3/4 inches
MAXIMUM depth of alcove = 48 inches
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
Figure 5 - Vertical Venting, Parallel or Alcove
Figure 7 - Alcove Size Requirements
8-11/16”
(221mm)
3*”
(76mm)
4-7/8*” (124mm)
5”
(127mm)
5”
(127mm)
Vertical Vent
8-11/16”
(221mm)
2” (51mm)
5”
(127mm)
5”
(127mm)
Horizontal Vent
33-3/4”
(857mm)
Minimum
60”
(1524mm)
Minimum
48”
(1220mm)
Max.
Figure 6 - Horizontal Vent, Parallel or Alcove
Vertical Vent
Corner Installations - Clearance to Combustibles
Combustible Wall
Combustible W
all
3-1/2” (89mm)
3-1/2”
(89mm)
Figure 4 - Vertical Venting
Top View
Top View
Top View
Combustible Wall
Combustible W
all
Combustible W
all
Combustible W
all
Combustible W
all
Combustible Wall
3*”
(76mm)
*Note: Refer to pipe Manufacturer's installation instructions
for minimum pipe clearances.
*Note: Refer to pipe Manufacturer's installation instructions
for minimum pipe clearances.