background image

11

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Top Log

Ports

Install front logs on retainer slots.

Place top log on pin.

Figure 10

Figure 11

s

urround

 p

anels

 i

nstallation

The Medina insert surround panels is made of heavy gage 

steel for durability and, if desired, for the ease of making an 

inside fit in the fireplace.

1.   Remove the speed nuts (A in Figure 12) from the parts 

bag and install (with the flat surface forward) on the 

six holes in the surround brackets - three on each side 

of the insert (B in Figure 12). A flat bladed screwdriver 

may help in installing the nuts.

2.   Install all surround panels and trim with the insert po-

sitioned in the fireplace but a few inches in front of its 

final location.

3.   Install the side surround panels by lining up the holes in 

the tabs on the side surround panels in front of the holes 

on the surround brackets.  Next insert two slotted 1/4" 

truss screws for each side surround panel and secure 

loosely. 

f

aCe

 i

nstallation

The faces come with hooked brackets. To install the face, 

hang the hooked brackets on the surround brackets (C in 

Figure 12).

Figure 1

A

B

C

Spring Handle Latches

Door Mounting Plates

Front Logs

4.   Fasten top surround panel with the remaining two truss 

screws. Tighten all six truss screws after adjusting the 

surround panels to eliminate space between side and 

top surround panels.

5.   Assemble the surround trim by inserting the elbowed 

retainer in the rectangular slot in the ends of the longest 

piece of trim and secure by tightening the screw in the 

retainer. Slide the mitred ends of the two side trim pieces 

onto the elbowed retainer and secure by tightening the 

retainer screw.

6.   The  fastened  trim  pieces  should  now  be  horseshoe 

shaped. Slide the trim down over the surround panels 

so the edge of the surround panel fits just behind the 

rounded edge of the trim.  

7.   Install three spring clips (found in parts bag in firebox) 

in  each  piece  of  trim  by  inserting  them  between  the 

rear of the surround panel and the channel of the trim. 

The spring clips will push the trim tight to the surround 

panel.

Summary of Contents for Direct-Vent Gas

Page 1: ...lez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz WARNING If the information in this man...

Page 2: ...lation 10 Surround Panels Installation 11 Face Installation 11 Gas Line Installation 12 Gas Pressure Requirements 12 LP Natural Gas Supplies 12 Air Shutter Adjustment 12 13 Operating Instructions 13 1...

Page 3: ...bsence of local codes with the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition Your Lennox gas insert must be equipped for...

Page 4: ...ucture Combustionairisdrawnfromoutside the structure When installing in a factory built fireplace the fireplace grate must be removed and the damper must be removed or secured open WARNING THIS FIREPL...

Page 5: ...The individual manual shut off must be a T handle type valve Commonwealth Of Massachusetts Requirements Note The following requirements reference various Massachusetts and national codes not contained...

Page 6: ...ired Insert Body Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Ins...

Page 7: ...ortionofthechimneysystemshowssigns of structural or mechanical weaknesses such as cracks leaky joints corroded or warped surfaces the faulty portion must be repaired or replaced prior to installing th...

Page 8: ...n the screws Repeat these steps for each adjusting leg G 13 330mm 10 254mm 0 0mm H 0 0mm 2 21mm 4 102mm E H F G J C L MANTEL TRIM Mantel Trim Hearth Floor Protection E 31 1 2 800mm from Top Facing to...

Page 9: ...1installationcode Theinsertmustnotbeconnected to a chimney flue serving a separate solid fuel burning ap pliance This gas insert requires a 3 diameter listed flex liner The vent should terminate with...

Page 10: ...the flue collar is removable see Flue Collar Connection If the factory built fireplace has no gas access hole s pro vided an access hole of 1 1 2 37 5 mm or less may be drilled through the lower sides...

Page 11: ...ure loosely Face Installation The faces come with hooked brackets To install the face hang the hooked brackets on the surround brackets C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounti...

Page 12: ...lve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig The appliance must be isolated from the gas supply piping...

Page 13: ...ghting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Page 14: ...knob slightly and turn clockwise to OFF Do not force This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air WARNIN...

Page 15: ...When the blower turns on the sound of rushing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking sound may be heard...

Page 16: ...e to determine the proper gage of wire for the thermostat or wall switch connections This table refers to the total length of the wire out to the switch and back The thermostat must be a millivolt typ...

Page 17: ...le and extend across the main burner ports Be careful not to back the screw out of its threads Replace the cover and check for gas leaks using a gas leak test solution oCheck that the area around the...

Page 18: ...reference Remove the insert face glass door and log set All of these items are fragile so handle them with care Next remove the nine allen head screws around the outside of the panel fastened to the b...

Page 19: ...pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot should...

Page 20: ...e Main Burner LP 53 H5951 Orifice High Altitude Main Burner LP 54 H5464 Conversion Kit NG to LP H5465 Conversion Kit LP to NG H6013 Blower w Mounting Bracket H5875 Blower Snap Switch H5655 Blower Spee...

Page 21: ...ase de H l appareil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FO...

Page 22: ...un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO...

Page 23: ...on about your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 877 247 3673 Replacemen...

Page 24: ...2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor fo...

Reviews: