NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

MINIMUM CLEARANCES TO COMBUSTIBLES

E = 31.5” (800mm) from Top Facing to Bottom of Insert

F = 25.5” (648mm) from Center of Glass to Side Facing or Side Wall

*J = 39” (991mm) from 10.5” (267mm) Mantel to Bottom of Insert

* See owner’s manual for additional mantel clearances and options

MINIMUM FIREPLACE SIZES REQUIRED

A=29.75” (756mm) Front Opening

B=17.50” (445mm) Height

C=19.00” (483mm) Rear Width

D=16.00” (406mm) Fireplace Depth

HEARTH PROTECTION
G = Minimum Hearth Protection

G =

 from Front of Insert

H = Vertical Distance from Insert

H =

 Bottom to Combustible Material

MODEL

MODÈLE

MEDINA™

MANUFACTURED BY / FABRIQUÉ PAR:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA., USA 98071

MED

SERIAL

 NO.

Report No. / Número de Rapport

 050-S-18b-5

LISTED VENTED GAS FIREPLACE HEATER - FIREPLACE INSERT - NOT FOR USE WITH SOLID FUEL

TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI 

Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED 

IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING 

FIREPLACES ONLY - MASONRY OR FACTORY BUILT.  THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. 

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN 

AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE 

OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED 

KIT IS USED.

DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. 

IF NOT, FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST 

EDITION (CANADA).

CHIMNEY - USE WITH B-VENT CHIMNEY OR SINGLE WALL GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.  

THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER’S 

INSTALLATION INSTRUCTIONS.

FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 

1,000 FT (405 M).

CAUTION:

HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS 

AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING 

INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS 

APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. 

REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN 

CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED 

WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED 

INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.

DO NOT REMOVE OR COVER THIS LABEL

Part No./ No. pièce #36241 Rev. A, 05/2007

FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.

CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT 

CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.

DÉGAGEMENTS AUX COMBUSTIBLES   

E =Dessus du foyer à partir de la base

31.5” (800mm)

F =Mur latéral à partir du centre du foyer

25.5

” (648mm)

*J =10.5” (267mm) manteau de foyer à partir de la base 39” (991mm)

* Voir le manuel d’entretien pour les informatinos supplémentaires reliées

   aux distances à respecter pour le manteau de foyer

DIMENSIONS MINIMUMS DE FOYER REQUISES

A = 29.75” (756mm) Ouverture avant

B = 17.50” (445mm) Hauteur

C = 19.00” (483mm) Largeur arrière

D = 16.00” (406mm) Profondeur du foyer

PROTECTION DU FOYER

G = Extension d’âtre min. devant

G =

 le foyer

H = Distance verticale de la base de

H =

 l’appareil aux combustibles

HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS 

UTILISER AVEC DU COMBUSTIBLE SOLIDE

TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.

CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION 

ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE 

INSTALLÉ SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE 

SOLIDE SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS 

CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.

CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ 

DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE 

MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES 

TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.

DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.

SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE 

CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.

CHEMINÉE - ÉVACUATION :INSTALLER AVEC DE L’ÉVENT À GAZ DE TYPE B-VENT OU UN CONDUIT FLEXIBLE À SIMPLE 

PAROI HOMOLOGUÉ COMME TUBAGE.

CET APPAREIL DOIT ÊTRE RELIÉ À UN SYSTÈME D’ÉVACUATION TEL QUE SPÉCIFIÉ DANS LE MANUEL D’INSTALLATION DU 

FABRICANT.

EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L’APPAREIL 

DIMINUE DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).

DANGER:

 CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES 

ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS 

LA PIÈCE. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES 

VAPEURS ET LIQUIDES INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT 

TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU 

VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE 

PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ 

PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE 

RÉPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. 

RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN 

INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ.

IGN

N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE

Medina (MED)

SPÉCIFICATIONS

GAZ NATUREL

GAZ PROPANE

ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 M)*

25000/17500

25000/18500

PRESSION À LA SORTIE  (IN. WC/C.E.)

3,5

10,0

PRESSION MINIMUM D’ENTRÉE DU GAZ (IN. WC/C.E.)

5,0

10,5

ORIFICE (DMS) 0-4500 pi (0-1370 M)*

#41

#53

* L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).

SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES 

MINIMUM CLEARANCES

E

H

F

G

J

CL

MANTEL

TRIM

Note: Hearth protection to be 

min. 3/8” (10mm) thick non-

combustible or equivalent, with 

a k factor of .84.

Note: Extension d’âtre fabriqué avec 

3/8” (10mm) minimum de matériaux 

non-combustible ou équivalent 

possédant un facteur k de 0.84.

DATE OF MANUFACTURE / DATE DE FABRICATION

2007

2009

2010

2008

JANV

JAN

FEVR

FEB

MARS

MAR

AVR

APR

MAI

MAY

JUIN

JUN

JUIL

JUL

AOÛT

AUG

SEPT

SEP

OCT

OCT

NOV

NOV

DEC

DEC

E

H

F

G

J

CL

DÉGAGEMENTS MINIMUMS

MANTEAU

DE FOYER

PIÈCE DE 

FINITION

Medina (MED)

RATINGS

NATURAL GAS

LP GAS

MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*

25,000/17,500

25,000/18,500

MANIFOLD PRESSURE (IN. WC)

3.5

10.0

MINIMUM INLET PRESSURE (IN. WC)

5.0

10.5

ORIFICE (DMS) 0-2,000 FT (0-610 M)*

#41

#53

*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M

ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS

G 13”(330mm) 10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

G 13”(330mm) 10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

SAFETY / LISTING LABEL

Summary of Contents for Direct-Vent Gas

Page 1: ...lez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz WARNING If the information in this man...

Page 2: ...lation 10 Surround Panels Installation 11 Face Installation 11 Gas Line Installation 12 Gas Pressure Requirements 12 LP Natural Gas Supplies 12 Air Shutter Adjustment 12 13 Operating Instructions 13 1...

Page 3: ...bsence of local codes with the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition Your Lennox gas insert must be equipped for...

Page 4: ...ucture Combustionairisdrawnfromoutside the structure When installing in a factory built fireplace the fireplace grate must be removed and the damper must be removed or secured open WARNING THIS FIREPL...

Page 5: ...The individual manual shut off must be a T handle type valve Commonwealth Of Massachusetts Requirements Note The following requirements reference various Massachusetts and national codes not contained...

Page 6: ...ired Insert Body Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Ins...

Page 7: ...ortionofthechimneysystemshowssigns of structural or mechanical weaknesses such as cracks leaky joints corroded or warped surfaces the faulty portion must be repaired or replaced prior to installing th...

Page 8: ...n the screws Repeat these steps for each adjusting leg G 13 330mm 10 254mm 0 0mm H 0 0mm 2 21mm 4 102mm E H F G J C L MANTEL TRIM Mantel Trim Hearth Floor Protection E 31 1 2 800mm from Top Facing to...

Page 9: ...1installationcode Theinsertmustnotbeconnected to a chimney flue serving a separate solid fuel burning ap pliance This gas insert requires a 3 diameter listed flex liner The vent should terminate with...

Page 10: ...the flue collar is removable see Flue Collar Connection If the factory built fireplace has no gas access hole s pro vided an access hole of 1 1 2 37 5 mm or less may be drilled through the lower sides...

Page 11: ...ure loosely Face Installation The faces come with hooked brackets To install the face hang the hooked brackets on the surround brackets C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounti...

Page 12: ...lve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig The appliance must be isolated from the gas supply piping...

Page 13: ...ghting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Page 14: ...knob slightly and turn clockwise to OFF Do not force This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air WARNIN...

Page 15: ...When the blower turns on the sound of rushing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking sound may be heard...

Page 16: ...e to determine the proper gage of wire for the thermostat or wall switch connections This table refers to the total length of the wire out to the switch and back The thermostat must be a millivolt typ...

Page 17: ...le and extend across the main burner ports Be careful not to back the screw out of its threads Replace the cover and check for gas leaks using a gas leak test solution oCheck that the area around the...

Page 18: ...reference Remove the insert face glass door and log set All of these items are fragile so handle them with care Next remove the nine allen head screws around the outside of the panel fastened to the b...

Page 19: ...pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot should...

Page 20: ...e Main Burner LP 53 H5951 Orifice High Altitude Main Burner LP 54 H5464 Conversion Kit NG to LP H5465 Conversion Kit LP to NG H6013 Blower w Mounting Bracket H5875 Blower Snap Switch H5655 Blower Spee...

Page 21: ...ase de H l appareil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FO...

Page 22: ...un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO...

Page 23: ...on about your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 877 247 3673 Replacemen...

Page 24: ...2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor fo...

Reviews: