background image

1

v

ent

 p

arts

 l

ist

Direct vent pipe Security™ Secure Vent™ * may be used 

with the Vision™ gas stove. Please see the lists below to 

verify the components available from each direct vent pipe 

manufacturer.  Snorkel  terminations  are  available  for  ap-

plications which may require vertical rise on the building 

exterior. The components listed below come in a galvanized 

finish. Most of the components are also available in a painted 

black finish. Add a “B” to the end of the part number when 

ordering if a black part is desired.

s

eCurity

 - s

eCure

 v

ent

 6-5/8”

x

 4” p

ipe

Part Number  Description

SV4LC   

6” Pipe Length

SV4L12   

12” Pipe Length

SV4L24   

24” Pipe Length

SV4L36   

36” Pipe Length

SV4L48   

48” Pipe Length

SV4LA   

6” Pipe, Adjustable

SV4LA12 

12” Pipe, Adjustable

SV4FA   

Flashing, 1/12 to 6/12 Roof Pitch

SV4FB   

Flashing, 7/12 to 12/12 Roof Pitch

SV4RSM  

Wall Radiation Shield

SV4E46   

45º Elbow

SV4E90   

90º Elbow

SV4VS   

Vinyl Shield Protector

SV4FC   

Storm Collar

SV4CGV  

Vertical Termination Cap

SV4BF   

Firestop

SV4CHC  

Horizontal Termination Cap

SV4STC36 

Snorkel Termination Cap (36”)

SV4STC14 

Snorkel Termination Cap (14”)

SV4BM   

Wall Band

Simpson Dura-Vent GS 6-5/8”x 4” Pipe

Part Number 

Description

908 

 

6” Pipe Length

907 

 

9” Pipe Length

906 

 

12” Pipe Length

904 

 

24” Pipe Length

903 

 

36” Pipe Length

902 

 

48” Pipe Length

911 

 

11” to 14-5/8” Pipe, Adjustable

942 

 

Wall Thimble

940 

 

Rnd Support Box/Wall Thimble Cover

941 

 

Cathedral Ceiling Support Box

943 

 

Flashing, 0/12 to 6/12 Roof Pitch

943S 

 

Flashing, 7/12 to 12/12 Roof Pitch

945 

 

45º Elbow

990 

 

90º Elbow

950 

 

Vinyl Siding Standoff

953 

 

Storm Collar

963 

 

Ceiling Firestop

988 

 

Wall Strap

981 

 

Snorkel Termination (36”)

982 

 

Snorkel Termination (14”)

984 

 

Horizontal Termination Cap

985 

 

Horizontal Termination Cap (High Wind)

980 

 

Vertical Termination Cap

991 

 

Vertical Termination Cap (High Wind)

h

orizontal

 v

ent

 i

nstallation

v

enting

 

terminals

 

may

 

not

 

be

 

reCessed

 

into

 

a

 

wall

 

or

 

siding

.

1) Set the unit in the desired location. Check whether or 

not wall studs are in the way when the venting system is 

attached.  If wall studs are in the way, you may want to 

adjust the location of the unit.

2) Assemble the desired combination of pipe and elbow to 

the appliance adaptor with pipe seams facing down. Off-

setting the pipe seams as double seams in one place will 

cause the outer pipe to take an oval shape. The Horizontal 

Termination  Kit comes with 18” of straight vent - 6-5/8” 

black outer pipe and 4” inner vent.

3) With the pipe attached to the stove, slide the stove into 

its correct location, and mark the wall to the dimensions 

of  the  wall  thimble  (9-1/4”  x  10-1/4”).  The  center  of 

the round hole should line up with the centerline of the 

horizontal pipe.  (9-1/4” is side-to-side dimension and 

10-1/4” is vertical dimension) If the wall being penetrated 

is constructed of non- combustible material (i.e. masonry 

block or concrete), a 7” diameter hole is acceptable.

4) The horizontal run of vent should have a 1/4” rise for every 

1 foot of run toward the termination. Never allow the vent    

to run downward. This could cause high temperatures 

and may present the possibility of a fire.

5) The location of the horizontal vent termination on an ex-

terior wall must meet all local and national building codes, 

and must not be blocked or obstructed. For External Vent 

Termination Locations, see page 13.

Snorkel Terminations:

  For installations requiring a vertical 

rise on the exterior of the building, 14-inch and 36-inch tall 

Snorkel Terminations are available, as well as the standard 

Riser  Vent.  Follow  the  same  installation  procedures  as 

used for standard Horizontal Termination. NEVER install the 

snorkel upside down.

Typical parts needed for a horizontal installation.

14” Snorkel for Vision 35

Standard Horizontal for Vision 25

Wall Thimble

Decorative Wall Trim

Pipe Length

max

min

Snorkel required for Vision 35 or

Vision 25 if horizontal run

exceeds 3 feet.

Figure 15

Summary of Contents for Gas Stove

Page 1: ...ppelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life AVERTISSEMENT Assurez vousdebiensuivrelesinstruc tionsdonnées danscettenoticepou...

Page 2: ... Vertical Vent Installation 13 Flue Restrictors 13 Horizontal Terminations 14 Vertical Terminations 14 Vent Termination Locations 15 Gas Line Installation 16 Gas Pressure Requirements 16 LP Natural Gas Supplies 16 Operating Instructions 17 20 Pre Lighting Checklist 17 Lighting Instructions 17 Flame Color Behavior 18 Air Shutter Adjustment 19 Quiet Operation 19 Paint Curing 19 Operating Options 20 ...

Page 3: ...ations ANSI A225 1 latest edition The appliance when installed must be electrically grounded in accordance with local codes or in the ab sence of local codes with the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition Your Lennox gas stove must be equipped for the proper fuel type altitude at which it will be operated Any op...

Page 4: ...e are any questions or if you need further substantiation either write to or call your Lennox Hearth Products dealer If you have further questions please contact Lennox Hearth Products The Vision Stove Mustconformwithalllocal state andnationalinstallation codes In the absence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 latest edition also known as NFPA 54 I...

Page 5: ...h The individual manual shut off must be a T handle type valve Commonwealth Of Massachusetts Requirements Note The following requirements reference various Massachusetts and national codes not contained in this document Forallsidewallhorizontallyventedgasfueledequipmentinstalledinevery dwelling building or structure used in whole or in part for residential purposes including those owned or operate...

Page 6: ...ore burns even during a power outage Fuel This stove comes from the factory equipped to burn natural gas at a specified elevation The stove can be converted to burnLPgas liquidpropane bychangingthecassette valve and pilot assembly or installing a conversion kit Only Len nox Hearth Products conversion kits can be used to convert from NG to LP or LP to NG Contact your Lennox Hearth Products dealer f...

Page 7: ...r other safety hazard The Lennox Hearth Products warranty will be voided if one of the following occurs Installation of any damaged stove or vent system component Unauthorized modification of the direct vent system Installation other than as instructed by Lennox Hearth Products Security Chimneys or Simpson Dura Vent Installationofanystoveorventsystemcomponentnot manufacturedorapprovedbyLennoxHeart...

Page 8: ...ls in inches millimeters Parallel Installation Corner Installation Alcove dimensions The minimum width between the alcove side walls is 51 1295mm Theminimumheightofthealcoveis46 1168mm and the maximum depth is 35 889mm Floor Protection A non combustible hearth pad is not required This stove may be installed on a combustible surface as long as the combustible material such as carpeting does not ext...

Page 9: ...ingcan create visible dimples on the plated surface To install the trim on the door first see Opening and Remov ing Door on page 22 Slide the threaded studs on the trim through the holes in the door Install the nuts on the studs to secure the trim to the door Do not over tighten the nuts or they will snap the studs off To install the spring handle first close the door and screw the handle into the...

Page 10: ...the brick retainer bracket from the upper left corner inside the stove Log Inserts 5 Place rockwool over ports Rockwool can be placed to obscure air holes but do not cover the air holes Fifty percent or less of rockwool supplied should be used in LP installations Too much rockwool will result in tall sooty flames 6 The right front log positioned with the black charred surface toward the front shou...

Page 11: ...em Installationofanyventcomponentpartnotapproved or manufactured by the approved vent manufac turer InstallationotherthanasinstructedbyLennoxHearth Products and vent manufacturers instructions Residential and Mobile Home Installations These are the minimum pieces required Other parts may be required for your particular installation Minimum Components for Horizontal Installation Horizontal Terminat...

Page 12: ... Vent Installation Venting terminals may not be recessed into a wall or siding 1 Set the unit in the desired location Check whether or not wall studs are in the way when the venting system is attached If wall studs are in the way you may want to adjust the location of the unit 2 Assemble the desired combination of pipe and elbow to the appliance adaptor with pipe seams facing down Off setting the ...

Page 13: ...s in the top of the firebox Restrictor positions are based on tests run in a laboratory StormCollar VerticalTermination Cap CeilingFirestop Framing 10 x 10 Roof Maintain 1 Clearance to Combustibles Pipe Length Flashing Handbreaktoremove unwantedrestrictor LightObstructor onlyusedforVision25w short horizontalrun nofluerestrictor Position1 FlueRestrictor Position3 Position2 A Vertical Vent Installat...

Page 14: ...Required No Light Obstructor Vision 35 NG 0 3 horizontal 14 Snorkel Required No Light Obstructor Offsets must remain within maximum and minimum lines To install the stove with pipe directly out the back a snorkel is not required for the Vision 25 gas stove A snorkel is required for the Vision 35 gas stove See pages 12 13 for snorkel installation instructions Vertical Terminations The diagram below...

Page 15: ...bove meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet 91 cm 3 feet 91 cm J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15 2 cm for appliances 10 000 BTU ...

Page 16: ...heck manifold pressure with the stove burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary Ifthepressureisnots...

Page 17: ...t push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DONOTusethisapplianceifanyparthasbeenunderwater Immediately call a qualified service technician to inspect theapplianceandtoreplaceanypartofthecontrolsystem and any gas control which has been under water OPERATING INSTRUCTIONS CAUTION Your Lennox gas AP...

Page 18: ... if installed to a setting below room temperature The pilot will remain lit for future burner igni tion For complete shutdown see TO TURN OFF GAS TO APPLIANCE above Flame Color Behavior Your Vision gas stove is designed for maximum heating efficiency Therefore upon lighting of the main burner the flames will be semi transparent or bluish After 10 20 minutes of operation the logs will heat up and t...

Page 19: ...teristics of the stove Quiet Operation As the Vision gas stove is burning a number of normal op erational sounds may be heard The flow of gas through the gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than 30 When the blower turns on the sound of rushi...

Page 20: ...er on and off indepen dently Be sure to set the rocker switch to the Off position when using the thermostat or remote control and set the thermostatorremotecontroltothelowesttemperaturewhen you wish to use the rocker switch only otherwise one may override the other Millivolt Control System This stove operates on a millivolt control system As such no additional power supply is needed for the stove ...

Page 21: ...rthegaspressurehasbeenchecked and supply lines have been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at the factory prior to shipment The pilot adjustment screw is located to the lower left of the flame height control knob 2 Adjust the pilot screw to properly size the flames The flames should completely surround the thermopile and...

Page 22: ...inserted in the slot at the bot tom of the firebox Glass Door Cleaning and Maintenance Cleaning Whencool theglassmaybecleanedwithaclean softclothandglasscleaner Forcleaningwhitecondensation from the interior glass use KEL KEM gas stove glass cleaner available from your stove dealer Use of caustic or abrasive cleaners may damage glass Gold or nickel plated trim must be cleaned with glass cleaner or...

Page 23: ...the two phillips head screws from the back of the burner 4 Lift the right end of the burner and slide if off the orifice and shutter tube Remove the burner from the firebox 5 Removethelabeledcoverthroughwhichthevalvecontrol knobs protrude by removing the two screws securing it and slide it off the valve knobs 6 Mark and disconnect wires on valve terminals 1 and 3 connected to the burner on off swi...

Page 24: ... pilot position for 1 2 minutes and light Check for spark at electrode and pilot if no spark and electrode wire is properly connected replace igniter See Lighting Instructions Pilot will not stay lit after carefully following lighting instructions Pilot flame is not sur rounding thermocouple Thermocouple not generating sufficient voltage Air in gas supply line Check pilot flame adjustment see Main...

Page 25: ...H5951 Orifice High Altitude Main Burner LP 25 000 BTU H5959 Orifice High Altitude Main Burner LP 35 000 BTU 75265 Conversion Kit NG to LP 75266 Conversion Kit LP to NG H3071 Blower H5875 Blower Snap Switch H5877 Blower Speed Control rheostat H5744 On Off Switch 46246 On Off Switch Wires H5745 Piezo Igniter 70006 Thermostat 70005 AC Remote Control Thermostat 71155 DC Remote Control Thermostat H5660...

Page 26: ...ors can cause improper and dangerous operation Verify proper operation after servicing POWER CORD SNAP SWITCH GRN 6 SPEED CONTROL SWITCH BLOWER BLK 6 RED 12 RED 7 RED 8 BLK 16 8 MALE SPADE 1 4 FEMALE SPADE 1 4 RING LUG CRIMP FEMALE SPADE 1 4 STRIP OUTER JACKET 6 W H T 6 2 PL FEMALE SPADE 1 4 FEMALE SPADE 1 4 MALE SPADE 1 4 FEMALE SPADE 1 4 Figure 31 ...

Page 27: ... service ou un fournisseur de gaz Si vous opérez cet appareil sans qu il ne soit correctement raccordé à un conduit d évacuation vous pourriez risquer d être empoisonné au monoxyde de carbone CO ce qui pourrait entraîner des conséquences grave ou la mort POUR COUPER L ALIMENTATION EN GAZ DE L APPAREIL 1 Pour arrêter le brûleur mettre l interrupteur à la position OFF ou ajustez le thermostat à une ...

Page 28: ...2 000 FT 0 610 M 35 000 23 000 35 000 23 500 25 000 17 500 25 000 18 000 MANIFOLD PRESSURE IN WC 3 5 10 0 3 5 10 0 MIN INLET PRESSURE IN WC 5 0 11 5 0 11 ORIFICE DMS 0 2 000 FT 0 610 M 34 111 IN 50 070 IN 42 093 IN 53 059 IN UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS DATE OF MANUFACTURE DATE DE FABRICATION 2007 2009 201...

Page 29: ...out your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 877 247 3673 Replacement parts See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox Hearth Products distributor or dealer Parts...

Page 30: ... 2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...

Reviews: