background image

7

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

CAUTION: YOUR COUNTRY GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE.  

STOP! Read the safety information above before proceeding.

1. Open the lower door.  Make sure gas supply shut-off cocks are open and ON/OFF 

Rocker Switch is “OFF”. If equipped with a thermostat, set it to the lowest setting.

2. Turn off all electrical power to the appliance.
3. Push in Gas Control Knob slightly and turn clockwise                 to “OFF”.

    NOTE: Knob cannot be turned from “PILOT” to “OFF” unless Knob is pushed in 

slightly. Do not force.

4. Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” above. If 

you don’t smell gas continue.

5.

Locate the pilot by looking at the center bottom of the back log. Blue flame will 

be seen when the pilot is lit.

6. Turn the gas control knob counterclockwise                to the “PILOT” position.
7. Push the knob all the way in and hold in that position. Immediately light the pilot by pressing the igniter 

button several times until pilot is lit. Continue to hold the knob in for about 30 seconds after the pilot is 

lit. Release knob and it will pop back out.  

    Pilot should remain lit. If it goes out, repeat steps 4-8 holding knob in an additional 15 seconds after 

pilot is lit.

• If knob does not pop out when released, stop and immediately call your service technician or gas 

supplier.

• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service 

technician or your gas supplier.

8. After pilot is lit, turn gas control counterclockwise                to “ON”.  Knob can only be turned “ON” if the knob has popped out.
9. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature above room temperature.

10. Adjust the flame height (and heat output) by turning the flame height knob clockwise                  for reduced flame and 

    counterclockwise                 for full flame.

11. Turn on all electrical power to the appliance. 
12. Set the blower to the desired air flow after it turns on when the appliance reaches operating temperature.

FOR YOUR SAFETY READ BEFORE OPERATING

1. To turn off the burner, switch the rocker switch to “OFF” or adjust the thermostat to a setting below room temperature          

(if installed). The pilot will remain lit for future burner ignition. 

For complete shutdown: See “TO TURN OFF GAS TO APPLIANCE” above.

SHUTDOWN PROCEDURE

OPERATING INSTRUCTIONS

WARNING:

 IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING 

PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.

CAUTION:

 HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH 

FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS DOOR OFF OR ATTEMPT TO OPEN THE DOOR WHILE HOT.

A. This appliance is equipped with a piezo ignition device to light the pilot. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air

and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

DO NOT try to light the appliance.

DO NOT touch any electric switch; do not use any phone in the building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use any tool. If the knob will not push in or turn by hand, don't try 

to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. DO NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance

and to replace any part of the control system and any gas control which has been under water.

1. Turn off the “ON/OFF” rocker switch and/or thermostat (if installed).
2. Turn off electric power to the appliance if service is to be performed.
3. Turn gas control knob clockwise                to "OFF". Do not force.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate 

combustion and ventilation air. See Installation and Operation Manual accompanying appliance.

WARNING:   Improper installation, adjustment, alteration, service or maintenance can 

cause injury or property damage. For assistance or additional information, consult a 

qualified installer, service agency or your gas supplier.

Operation of this appliance when not connected to a properly installed and maintained venting system can result 

in carbon monoxide (CO) poisoning and possible death.

TO TURN OFF GAS TO APPLIANCE

POUR VOTRE SÉCURITÉ, LIRE AVANT L’ALLUMAGE

1. Fermez l’interrupteur et/ou le thermostat «MARCHE/ARRÊT».
2. Coupez l’alimentation électrique de l’appareil si vous prévoyez en faire le service.
3. Tournez le bouton de commande du gaz dans le sens des aiguilles d’une montre                à “OFF”. Ne le forcez pas.

Cet appareil a besoin d’air frais pour opérer sécritairement et doit être installé pour qu’il y ait un apport en air suffisant. Référez-vous 

aux manuels d’entretien et d’installation fournis avec l’appareil.

AVERTISSEMENT: Une installation inadéquate, un mauvais ajustement, une altération ou toutes autres modifications 

inappropriés pourraient entraîner des blessures physiques et/ou des dommanges matériels. Référez-vous au guide 

d’utilisation fourni avec ce foyer. Pour assistance ou information supplémentaires contactez un installateur qualifié, 

un agent de service ou un fournisseur de gaz.

Si vous opérez cet appareil sans qu’il ne soit correctement raccordé à un conduit d’évacuation, vous pourriez risquer d’être 

empoisonné au monoxyde de carbone (CO) ce qui pourrait entraîner des conséquences grave ou la mort.

POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL

1. Pour arrêter le brûleur, mettre l’interrupteur à la position “OFF” ou ajustez le thermostat à une température en dessous de la 

température ambiante. La veilleuse restera allumée pour permettre un alummage ultérieur. 
Pour un arrêt complet: Consultez la procédure ci-dessus «POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL».

PROCÉDURE D’ARRÊT

ALLUMAGE

AVERTISSEMENT:

 SI VOUS NE RESPECTEZ PAS RIGOUREUSEMENT LES INSTRUCTIONS CI-DESSOUS, VOUS POURRIEZ ENCOURIR UN RISQUE D’INCENDIE ET/OU 

D’EXPLOSION QUI POURRAIENT CAUSER DES DOMMANGES MATÉRIELS ET CORPORELS POUVANT ENTRAÎNER LA MORT.

DANGER:

 CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET 

RIDEAUX. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES.

A. Cet appareil utilise un système d’allumage par étincelle (allumeur Piézo-électrique) pour allumer la veilleuse. Assurez-vous de suivre

rigoureusement les instructions d’allumage de la veilleuse.

B. AVANT D’ALLUMER L’APPAREIL, assurez-vous qu’il n’y a pas d’odeur de gaz près de l’appareil ni près du sol car certains gaz plus

lourds que l’air auraient tendance à s’y accumuler en cas de fuite.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• N’ALLUMEZ aucun appareil.

• Ne touchez aucune prise électrique; N’utilisez aucun téléphone dans votre édifice.

• Sortez de la maison. À partir d’un autre endroit, appelez immédiatement votre fournisseur de gaz et suivez les directives.

• S’il est impossible de joindre le distributeur du gaz, appelez les pompiers.

C. N’utilisez aucun outil pour tourner ou pousser le dispositif de contrôle du gaz. Si vous ne pouvez le faire manuellement, n’essayez

pas de réparer l’appareil. Appelez un technicien de service qualifié. Si vous tentez de forcer ou réparer le dispositif de contrôle du gaz

vous pourriez encourir un risque d’incendie et/ou d’explosion.

D. N’utilisez pas cet appareil si une de ses composantes a été émergée dans l’eau. Appelez immédiatement un technicien de service

qualifié et reconnu  afin qu’il inspecte et remplace au besoin toutes pièces du système qui auraient été en contact avec l’eau.

DANGER: VOTRE APPAREIL AU GAZ LENNOX DOIT ÊTRE OPÉRÉ AVEC DES PORTES DE VERRE.  

ATTENTION! Lisez les consignes de sécurité ci-dessous avant d’opérer votre appareil.

1. Ouvrir  la  porte  du  bas.  Assurez-vous  que  l’alimentation  en  gaz  est  à  la  position  Fermée  “OFF”.  Si  l’appareil  est

    équippé d’un thermostat, placez-le à la température la plus basse.

2. Couper le courant électrique qui alimente l’appareil.

3. Enfoncez légèrement le bouton de contrôle du gaz et tournez-le dans le sens des aiguilles d’une montre                    à la position “OFF”.

NOTE: Le bouton de contrôle du gaz ne peut être tourné de la position “PILOT” à “OFF” sans qu’une légère pression ne soit appliquée.

4. Attendez au moins 5 minutes pour que le gaz qui se trouve dans la chambre de combustion puissse s’échapper. Si vous sentez une

    odeur de gaz ARRÊTEZ! Référez-vous à la section B ci-dessus. Si vous ne sentez pas d’odeur de gaz, allez à la prochaine étape.

5.   

Localisez le  pilote au centre dans le bas de la bûche arrière.  Une flamme bleue est visible lorsque le veilleuse est   

          allumée.

6. Tournez le bouton de contrôle de gaz dans le sens inverse des aiguilles d’une montre                    pour le placer sur “PILOT”.

7. Cet appareil de chauffage est equipé d’un système d’allumage par étincelle (allumeur Piézo-électirque), devant être utilisé pour

    l’allumage de la veilleuse. Poussez complètement le bouton de contrôle du gaz et le maintenir dans cette position. Appuyez

    immédiatement sur le bouton (allumeur Piézo-électrique) situé à gauche du robinet de contrôle du gaz.L’étincelle produite par

    l’allumeur Piézo-électrique doit allumer la veilleuse. Continuez à maintenir le bouton de contrôle dans cette position pendant environ 30

    secondes après l’allumage de la veilleuse. Relâchez le bouton de contrôle du gaz qui reviendra à la position initiale. La veilleuse doit

    rester allumée. Répétez les étapes 4 à 8 pendant 15 secondes supplémentaires si la veilleuse s’éteind.

• Si le bouton de contrôle du gaz ne revient pas à la position initiale une fois relâché, appeler immédiatement un technicien qualifié ou

    votre distributeur de gaz.

• Si la veileuse ne reste pas allumée après plusieurs essais, tournez le bouton de contrôle du gaz à la position “OFF” et appelez

    immédiatement un technicien qualifié ou votre distributeur de gaz.

8. Lorsque la veilleuse est allumée, tournez le bouton de contrôle du gaz dans le sens invers des aiguilles d’une montre                pour le

    placer à la position “ON”. Le bouton de contrôle peut-être tourné à la position “ON” seulement si il n’est plus enfoncé.

9. Pour allumer le brûleur, mettre l’interrupteur à la position “ON” ou ajustez le thermostat à la température souhaitée.

10. Ajustez la flamme et la température souhaitée en tournant le bouton de réglage de la flamme dans les sens des aiguille d’une montre    

                     pour l’abaisser et dans le sens contraire                   pour l’augmenter.

11.   Allumez l’alimentation  électrique de l’appareil.

12.   Ajustez le ventilateur au volume désiré lorsque l’appareil aura atteint la température de fonctionnement.

Part No./ No. Pièce #36242 Rev. A, 04/07

PILOT ASSEMBLY

Thermopile

Veilleuse à gaz Igniter (electrode)

Allumeur

Thermocouple

Gas Pilot Hood

IGN

Gas Control Knob (pilot/on/off)

Bouton de contrôle (veilleuse/

ouverte/fermée)

Flame Height 

Control Knob

- LO / HI + 

(Commande De

Taille De Flamme)

ON

PILO

T

OFF

HI

LO

Blower /

Ventilateur

On/Off Switch / 

Interrupteur

Igniter /

Allumeur

Lighting Label

Summary of Contents for Gas Stove

Page 1: ...ppelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life AVERTISSEMENT Assurez vousdebiensuivrelesinstruc tionsdonnées danscettenoticepou...

Page 2: ... Vertical Vent Installation 13 Flue Restrictors 13 Horizontal Terminations 14 Vertical Terminations 14 Vent Termination Locations 15 Gas Line Installation 16 Gas Pressure Requirements 16 LP Natural Gas Supplies 16 Operating Instructions 17 20 Pre Lighting Checklist 17 Lighting Instructions 17 Flame Color Behavior 18 Air Shutter Adjustment 19 Quiet Operation 19 Paint Curing 19 Operating Options 20 ...

Page 3: ...ations ANSI A225 1 latest edition The appliance when installed must be electrically grounded in accordance with local codes or in the ab sence of local codes with the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition Your Lennox gas stove must be equipped for the proper fuel type altitude at which it will be operated Any op...

Page 4: ...e are any questions or if you need further substantiation either write to or call your Lennox Hearth Products dealer If you have further questions please contact Lennox Hearth Products The Vision Stove Mustconformwithalllocal state andnationalinstallation codes In the absence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 latest edition also known as NFPA 54 I...

Page 5: ...h The individual manual shut off must be a T handle type valve Commonwealth Of Massachusetts Requirements Note The following requirements reference various Massachusetts and national codes not contained in this document Forallsidewallhorizontallyventedgasfueledequipmentinstalledinevery dwelling building or structure used in whole or in part for residential purposes including those owned or operate...

Page 6: ...ore burns even during a power outage Fuel This stove comes from the factory equipped to burn natural gas at a specified elevation The stove can be converted to burnLPgas liquidpropane bychangingthecassette valve and pilot assembly or installing a conversion kit Only Len nox Hearth Products conversion kits can be used to convert from NG to LP or LP to NG Contact your Lennox Hearth Products dealer f...

Page 7: ...r other safety hazard The Lennox Hearth Products warranty will be voided if one of the following occurs Installation of any damaged stove or vent system component Unauthorized modification of the direct vent system Installation other than as instructed by Lennox Hearth Products Security Chimneys or Simpson Dura Vent Installationofanystoveorventsystemcomponentnot manufacturedorapprovedbyLennoxHeart...

Page 8: ...ls in inches millimeters Parallel Installation Corner Installation Alcove dimensions The minimum width between the alcove side walls is 51 1295mm Theminimumheightofthealcoveis46 1168mm and the maximum depth is 35 889mm Floor Protection A non combustible hearth pad is not required This stove may be installed on a combustible surface as long as the combustible material such as carpeting does not ext...

Page 9: ...ingcan create visible dimples on the plated surface To install the trim on the door first see Opening and Remov ing Door on page 22 Slide the threaded studs on the trim through the holes in the door Install the nuts on the studs to secure the trim to the door Do not over tighten the nuts or they will snap the studs off To install the spring handle first close the door and screw the handle into the...

Page 10: ...the brick retainer bracket from the upper left corner inside the stove Log Inserts 5 Place rockwool over ports Rockwool can be placed to obscure air holes but do not cover the air holes Fifty percent or less of rockwool supplied should be used in LP installations Too much rockwool will result in tall sooty flames 6 The right front log positioned with the black charred surface toward the front shou...

Page 11: ...em Installationofanyventcomponentpartnotapproved or manufactured by the approved vent manufac turer InstallationotherthanasinstructedbyLennoxHearth Products and vent manufacturers instructions Residential and Mobile Home Installations These are the minimum pieces required Other parts may be required for your particular installation Minimum Components for Horizontal Installation Horizontal Terminat...

Page 12: ... Vent Installation Venting terminals may not be recessed into a wall or siding 1 Set the unit in the desired location Check whether or not wall studs are in the way when the venting system is attached If wall studs are in the way you may want to adjust the location of the unit 2 Assemble the desired combination of pipe and elbow to the appliance adaptor with pipe seams facing down Off setting the ...

Page 13: ...s in the top of the firebox Restrictor positions are based on tests run in a laboratory StormCollar VerticalTermination Cap CeilingFirestop Framing 10 x 10 Roof Maintain 1 Clearance to Combustibles Pipe Length Flashing Handbreaktoremove unwantedrestrictor LightObstructor onlyusedforVision25w short horizontalrun nofluerestrictor Position1 FlueRestrictor Position3 Position2 A Vertical Vent Installat...

Page 14: ...Required No Light Obstructor Vision 35 NG 0 3 horizontal 14 Snorkel Required No Light Obstructor Offsets must remain within maximum and minimum lines To install the stove with pipe directly out the back a snorkel is not required for the Vision 25 gas stove A snorkel is required for the Vision 35 gas stove See pages 12 13 for snorkel installation instructions Vertical Terminations The diagram below...

Page 15: ...bove meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet 91 cm 3 feet 91 cm J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15 2 cm for appliances 10 000 BTU ...

Page 16: ...heck manifold pressure with the stove burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary Ifthepressureisnots...

Page 17: ...t push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DONOTusethisapplianceifanyparthasbeenunderwater Immediately call a qualified service technician to inspect theapplianceandtoreplaceanypartofthecontrolsystem and any gas control which has been under water OPERATING INSTRUCTIONS CAUTION Your Lennox gas AP...

Page 18: ... if installed to a setting below room temperature The pilot will remain lit for future burner igni tion For complete shutdown see TO TURN OFF GAS TO APPLIANCE above Flame Color Behavior Your Vision gas stove is designed for maximum heating efficiency Therefore upon lighting of the main burner the flames will be semi transparent or bluish After 10 20 minutes of operation the logs will heat up and t...

Page 19: ...teristics of the stove Quiet Operation As the Vision gas stove is burning a number of normal op erational sounds may be heard The flow of gas through the gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than 30 When the blower turns on the sound of rushi...

Page 20: ...er on and off indepen dently Be sure to set the rocker switch to the Off position when using the thermostat or remote control and set the thermostatorremotecontroltothelowesttemperaturewhen you wish to use the rocker switch only otherwise one may override the other Millivolt Control System This stove operates on a millivolt control system As such no additional power supply is needed for the stove ...

Page 21: ...rthegaspressurehasbeenchecked and supply lines have been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at the factory prior to shipment The pilot adjustment screw is located to the lower left of the flame height control knob 2 Adjust the pilot screw to properly size the flames The flames should completely surround the thermopile and...

Page 22: ...inserted in the slot at the bot tom of the firebox Glass Door Cleaning and Maintenance Cleaning Whencool theglassmaybecleanedwithaclean softclothandglasscleaner Forcleaningwhitecondensation from the interior glass use KEL KEM gas stove glass cleaner available from your stove dealer Use of caustic or abrasive cleaners may damage glass Gold or nickel plated trim must be cleaned with glass cleaner or...

Page 23: ...the two phillips head screws from the back of the burner 4 Lift the right end of the burner and slide if off the orifice and shutter tube Remove the burner from the firebox 5 Removethelabeledcoverthroughwhichthevalvecontrol knobs protrude by removing the two screws securing it and slide it off the valve knobs 6 Mark and disconnect wires on valve terminals 1 and 3 connected to the burner on off swi...

Page 24: ... pilot position for 1 2 minutes and light Check for spark at electrode and pilot if no spark and electrode wire is properly connected replace igniter See Lighting Instructions Pilot will not stay lit after carefully following lighting instructions Pilot flame is not sur rounding thermocouple Thermocouple not generating sufficient voltage Air in gas supply line Check pilot flame adjustment see Main...

Page 25: ...H5951 Orifice High Altitude Main Burner LP 25 000 BTU H5959 Orifice High Altitude Main Burner LP 35 000 BTU 75265 Conversion Kit NG to LP 75266 Conversion Kit LP to NG H3071 Blower H5875 Blower Snap Switch H5877 Blower Speed Control rheostat H5744 On Off Switch 46246 On Off Switch Wires H5745 Piezo Igniter 70006 Thermostat 70005 AC Remote Control Thermostat 71155 DC Remote Control Thermostat H5660...

Page 26: ...ors can cause improper and dangerous operation Verify proper operation after servicing POWER CORD SNAP SWITCH GRN 6 SPEED CONTROL SWITCH BLOWER BLK 6 RED 12 RED 7 RED 8 BLK 16 8 MALE SPADE 1 4 FEMALE SPADE 1 4 RING LUG CRIMP FEMALE SPADE 1 4 STRIP OUTER JACKET 6 W H T 6 2 PL FEMALE SPADE 1 4 FEMALE SPADE 1 4 MALE SPADE 1 4 FEMALE SPADE 1 4 Figure 31 ...

Page 27: ... service ou un fournisseur de gaz Si vous opérez cet appareil sans qu il ne soit correctement raccordé à un conduit d évacuation vous pourriez risquer d être empoisonné au monoxyde de carbone CO ce qui pourrait entraîner des conséquences grave ou la mort POUR COUPER L ALIMENTATION EN GAZ DE L APPAREIL 1 Pour arrêter le brûleur mettre l interrupteur à la position OFF ou ajustez le thermostat à une ...

Page 28: ...2 000 FT 0 610 M 35 000 23 000 35 000 23 500 25 000 17 500 25 000 18 000 MANIFOLD PRESSURE IN WC 3 5 10 0 3 5 10 0 MIN INLET PRESSURE IN WC 5 0 11 5 0 11 ORIFICE DMS 0 2 000 FT 0 610 M 34 111 IN 50 070 IN 42 093 IN 53 059 IN UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS DATE OF MANUFACTURE DATE DE FABRICATION 2007 2009 201...

Page 29: ...out your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 877 247 3673 Replacement parts See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox Hearth Products distributor or dealer Parts...

Page 30: ... 2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...

Reviews: