background image

8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

VIS

ALCOVE DIMENSIONS -  DIMENSIONS – ALCOVE

MAXIMUM DEPTH / PROFONDEUR MAXIMUM 35”(889mm)

MINIMUM WIDTH / LARGEUR MAXIMUM 51”(1295mm)

MINIMUM HEIGHT / HAUTEUR MAXIMUM 46”(1168mm)

SEE OWNER’S MANUAL FOR OTHER ALCOVE 

CLEARANCE CONFIGURATIONS.

RÉFÉREZ VOUS AU MANUEL D’INSTALLATION 

POUR TOUT AUTRE DÉGAGEMENT REQUIS.

HEARTH PROTECTION

SEE INSTRUCTION MANUAL.

PROTECTIONS AU PLANCHER : RÉFÉREZ 

VOUS AU MANUEL D’INSTALLATION.

* 16.5” (1295Mm) to sidewall in an alcove 

* Dégagement des matériaux 

  Combustible pour les murs de côté 

  Dans une alcôve est 16.5 Po (1295mm)

  De chaque côté.

MINIMUM CLEARANCES TO COMBUSTIBLES IN INCHES

DÉGAGEMENTS AUX COMBUSTIBLES - POUCES

2"

(51mm)

*15"

(381mm)

Co

m

bu

sti

ble

 W

all

Mur Combustible

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL

MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.

TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI 

Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA)

 AND SAFETY STANDARD, TITLE 24 CFR, 

PART 3280 FOR MOBILE HOMES.  ALSO, APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S 

INSTALLATION INSTRUCTIONS.

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN 

AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. 

SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A 

CERTIFIED KIT IS USED.

DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. 

IF NOT, FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST 

EDITION (CANADA).

VENTING: THIS APPLIANCE  MUST  BE  PROPERLY  CONNECTED  TO A  VENTING  SYSTEM  IN ACCORDANCE  WITH  THE 

MANUFACTURER’S INSTRUCTIONS. SEE MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR APPROVED PIPE BRANDS 

AND PIPE SEALING PROCEDURES.

FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 

FT (405 M).
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.

Part No./ No. Pièce #36242 Rev. A, 05/2007

DO NOT REMOVE OR COVER THIS LABEL

MADE IN U.S.A.

CAUTION:

HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS 

AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING 

INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS 

APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. 

REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN 

CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED 

WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED 

INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.

ALCOVE OR PARALLEL / 

POSITION PARALLÈLE OU 

POSITION DE L'ALCÔVE

CORNER / 

POSITION

EN COIN

MANUFACTURED BY / FABRIQUÉ PAR:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA., USA 98071

MODEL

VISION™

MODÈLE

Report No. / Número de Rapport

050-S-16b-5

SERIAL

 NO.

FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.

CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT 

CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.

RATINGS

Vision 35 (VIS35)

Vision 25 (VIS25)

NATURAL GAS

LP GAS

NATURAL GAS

LP GAS

MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*

35,000/23,000

35,000/23,500

25,000/17,500

25,000/18,000

MANIFOLD PRESSURE (IN. WC)

3.5

10.0

3.5

10.0

MIN. INLET PRESSURE (IN. WC)

5.0

11

5.0

11

ORIFICE (DMS) 0-2,000 FT (0-610 M)*

#34/.111 IN.

#50/.070 IN.

#42/.093 IN.

#53/.059 IN.

*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M

ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS

DATE OF MANUFACTURE / DATE DE FABRICATION

2007

2009

2010

2008

JANV

JAN

FEVR

FEB

MARS

MAR

AVR

APR

MAI

MAY

JUIN

JUN

JUIL

JUL

AOÛT

AUG

SEPT

SEP

OCT

OCT

NOV

NOV

DEC

DEC

90°

    5-5/8”

(143mm)

10”

(254mm)

10”

(254mm)

8-7/8”

 (225mm)

Co

mb

ust

ible

 Wa

ll

Mur C

omb

ustib

le

HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU 

GAZ -NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE

MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.
TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.
CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION 

ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA) POUR LES MAISON MOBILE 

LE STANDARD DE SÉCURITÉ EST TITLE 24CFR, PART 3280 .  CET APPAREIL DOIT ÊTRE INSTALLER SELON LES SPÉCIFICATIONS 

DU MANUFACTURIER.
CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ 

DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE 

MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES 

TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.
SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE 

CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.

CONDUIT:  CET  APPAREIL  DOIT  ÊTRE  INSTALLER  SEULEMENT  AVEC  UN  CONDUIT  D’ÉVACUATION 

RECOMMANDÉ PAR LE MANUFACTURIER.  TOUJOURS SE RÉFÉRER AU MANUEL D’INSTALLATION.
EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE 

L’APPAREIL DIMINUE DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).
CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.

DANGER:

CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE 

INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. 

SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE. GARDEZ LA ZONE AUTOUR DU 

FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES 

INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT 

TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. 

SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. 

EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE 

REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE  INSTALLATION  INADÉQUATE  DE  MÊME  QU’UN  AJUSTEMENT,  UNE 

MODIFICATION,  UNE  RÉPARATION  OU  UN  ENTRETIEN  INCORRECTS  PEUVENT  CAUSER  DES 

BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC 

CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE 

DE SERVICE OU UN FOURNISSEUR DE GAZ.

SPÉCIFICATIONS

Vision 35 (VIS35)

Vision 25 (VIS25)

GAZ NATUREL

GAZ PROPANE

GAZ NATUREL

GAZ PROPANE

ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 

M)*

35000/23000 35000/23500 25000/17500

25000/18000

PRESSION À LA SORTIE  (IN. WC/C.E.)

3.5

10.0

3.5

10.0

PRESSION MINIMUM D’ENTRÉE DU GAZ 

(IN. WC/C.E.)

5.0

11

5.0

11

ORIFICE (DMS) 0-4500 pi (0-1370 M)*

#34/.111"

#50/.070"

#42/.093"

#53/.059"

* L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).

SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES 

NE PAS RETIRER CETTE ÉTIQUETTE        

Fabriqué aux  U.S.A.

IGN

Poêle

Poêle

Stove

Stove

Safety / Listing Label

Summary of Contents for Gas Stove

Page 1: ...ppelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life AVERTISSEMENT Assurez vousdebiensuivrelesinstruc tionsdonnées danscettenoticepou...

Page 2: ... Vertical Vent Installation 13 Flue Restrictors 13 Horizontal Terminations 14 Vertical Terminations 14 Vent Termination Locations 15 Gas Line Installation 16 Gas Pressure Requirements 16 LP Natural Gas Supplies 16 Operating Instructions 17 20 Pre Lighting Checklist 17 Lighting Instructions 17 Flame Color Behavior 18 Air Shutter Adjustment 19 Quiet Operation 19 Paint Curing 19 Operating Options 20 ...

Page 3: ...ations ANSI A225 1 latest edition The appliance when installed must be electrically grounded in accordance with local codes or in the ab sence of local codes with the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition Your Lennox gas stove must be equipped for the proper fuel type altitude at which it will be operated Any op...

Page 4: ...e are any questions or if you need further substantiation either write to or call your Lennox Hearth Products dealer If you have further questions please contact Lennox Hearth Products The Vision Stove Mustconformwithalllocal state andnationalinstallation codes In the absence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 latest edition also known as NFPA 54 I...

Page 5: ...h The individual manual shut off must be a T handle type valve Commonwealth Of Massachusetts Requirements Note The following requirements reference various Massachusetts and national codes not contained in this document Forallsidewallhorizontallyventedgasfueledequipmentinstalledinevery dwelling building or structure used in whole or in part for residential purposes including those owned or operate...

Page 6: ...ore burns even during a power outage Fuel This stove comes from the factory equipped to burn natural gas at a specified elevation The stove can be converted to burnLPgas liquidpropane bychangingthecassette valve and pilot assembly or installing a conversion kit Only Len nox Hearth Products conversion kits can be used to convert from NG to LP or LP to NG Contact your Lennox Hearth Products dealer f...

Page 7: ...r other safety hazard The Lennox Hearth Products warranty will be voided if one of the following occurs Installation of any damaged stove or vent system component Unauthorized modification of the direct vent system Installation other than as instructed by Lennox Hearth Products Security Chimneys or Simpson Dura Vent Installationofanystoveorventsystemcomponentnot manufacturedorapprovedbyLennoxHeart...

Page 8: ...ls in inches millimeters Parallel Installation Corner Installation Alcove dimensions The minimum width between the alcove side walls is 51 1295mm Theminimumheightofthealcoveis46 1168mm and the maximum depth is 35 889mm Floor Protection A non combustible hearth pad is not required This stove may be installed on a combustible surface as long as the combustible material such as carpeting does not ext...

Page 9: ...ingcan create visible dimples on the plated surface To install the trim on the door first see Opening and Remov ing Door on page 22 Slide the threaded studs on the trim through the holes in the door Install the nuts on the studs to secure the trim to the door Do not over tighten the nuts or they will snap the studs off To install the spring handle first close the door and screw the handle into the...

Page 10: ...the brick retainer bracket from the upper left corner inside the stove Log Inserts 5 Place rockwool over ports Rockwool can be placed to obscure air holes but do not cover the air holes Fifty percent or less of rockwool supplied should be used in LP installations Too much rockwool will result in tall sooty flames 6 The right front log positioned with the black charred surface toward the front shou...

Page 11: ...em Installationofanyventcomponentpartnotapproved or manufactured by the approved vent manufac turer InstallationotherthanasinstructedbyLennoxHearth Products and vent manufacturers instructions Residential and Mobile Home Installations These are the minimum pieces required Other parts may be required for your particular installation Minimum Components for Horizontal Installation Horizontal Terminat...

Page 12: ... Vent Installation Venting terminals may not be recessed into a wall or siding 1 Set the unit in the desired location Check whether or not wall studs are in the way when the venting system is attached If wall studs are in the way you may want to adjust the location of the unit 2 Assemble the desired combination of pipe and elbow to the appliance adaptor with pipe seams facing down Off setting the ...

Page 13: ...s in the top of the firebox Restrictor positions are based on tests run in a laboratory StormCollar VerticalTermination Cap CeilingFirestop Framing 10 x 10 Roof Maintain 1 Clearance to Combustibles Pipe Length Flashing Handbreaktoremove unwantedrestrictor LightObstructor onlyusedforVision25w short horizontalrun nofluerestrictor Position1 FlueRestrictor Position3 Position2 A Vertical Vent Installat...

Page 14: ...Required No Light Obstructor Vision 35 NG 0 3 horizontal 14 Snorkel Required No Light Obstructor Offsets must remain within maximum and minimum lines To install the stove with pipe directly out the back a snorkel is not required for the Vision 25 gas stove A snorkel is required for the Vision 35 gas stove See pages 12 13 for snorkel installation instructions Vertical Terminations The diagram below...

Page 15: ...bove meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet 91 cm 3 feet 91 cm J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15 2 cm for appliances 10 000 BTU ...

Page 16: ...heck manifold pressure with the stove burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary Ifthepressureisnots...

Page 17: ...t push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DONOTusethisapplianceifanyparthasbeenunderwater Immediately call a qualified service technician to inspect theapplianceandtoreplaceanypartofthecontrolsystem and any gas control which has been under water OPERATING INSTRUCTIONS CAUTION Your Lennox gas AP...

Page 18: ... if installed to a setting below room temperature The pilot will remain lit for future burner igni tion For complete shutdown see TO TURN OFF GAS TO APPLIANCE above Flame Color Behavior Your Vision gas stove is designed for maximum heating efficiency Therefore upon lighting of the main burner the flames will be semi transparent or bluish After 10 20 minutes of operation the logs will heat up and t...

Page 19: ...teristics of the stove Quiet Operation As the Vision gas stove is burning a number of normal op erational sounds may be heard The flow of gas through the gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than 30 When the blower turns on the sound of rushi...

Page 20: ...er on and off indepen dently Be sure to set the rocker switch to the Off position when using the thermostat or remote control and set the thermostatorremotecontroltothelowesttemperaturewhen you wish to use the rocker switch only otherwise one may override the other Millivolt Control System This stove operates on a millivolt control system As such no additional power supply is needed for the stove ...

Page 21: ...rthegaspressurehasbeenchecked and supply lines have been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at the factory prior to shipment The pilot adjustment screw is located to the lower left of the flame height control knob 2 Adjust the pilot screw to properly size the flames The flames should completely surround the thermopile and...

Page 22: ...inserted in the slot at the bot tom of the firebox Glass Door Cleaning and Maintenance Cleaning Whencool theglassmaybecleanedwithaclean softclothandglasscleaner Forcleaningwhitecondensation from the interior glass use KEL KEM gas stove glass cleaner available from your stove dealer Use of caustic or abrasive cleaners may damage glass Gold or nickel plated trim must be cleaned with glass cleaner or...

Page 23: ...the two phillips head screws from the back of the burner 4 Lift the right end of the burner and slide if off the orifice and shutter tube Remove the burner from the firebox 5 Removethelabeledcoverthroughwhichthevalvecontrol knobs protrude by removing the two screws securing it and slide it off the valve knobs 6 Mark and disconnect wires on valve terminals 1 and 3 connected to the burner on off swi...

Page 24: ... pilot position for 1 2 minutes and light Check for spark at electrode and pilot if no spark and electrode wire is properly connected replace igniter See Lighting Instructions Pilot will not stay lit after carefully following lighting instructions Pilot flame is not sur rounding thermocouple Thermocouple not generating sufficient voltage Air in gas supply line Check pilot flame adjustment see Main...

Page 25: ...H5951 Orifice High Altitude Main Burner LP 25 000 BTU H5959 Orifice High Altitude Main Burner LP 35 000 BTU 75265 Conversion Kit NG to LP 75266 Conversion Kit LP to NG H3071 Blower H5875 Blower Snap Switch H5877 Blower Speed Control rheostat H5744 On Off Switch 46246 On Off Switch Wires H5745 Piezo Igniter 70006 Thermostat 70005 AC Remote Control Thermostat 71155 DC Remote Control Thermostat H5660...

Page 26: ...ors can cause improper and dangerous operation Verify proper operation after servicing POWER CORD SNAP SWITCH GRN 6 SPEED CONTROL SWITCH BLOWER BLK 6 RED 12 RED 7 RED 8 BLK 16 8 MALE SPADE 1 4 FEMALE SPADE 1 4 RING LUG CRIMP FEMALE SPADE 1 4 STRIP OUTER JACKET 6 W H T 6 2 PL FEMALE SPADE 1 4 FEMALE SPADE 1 4 MALE SPADE 1 4 FEMALE SPADE 1 4 Figure 31 ...

Page 27: ... service ou un fournisseur de gaz Si vous opérez cet appareil sans qu il ne soit correctement raccordé à un conduit d évacuation vous pourriez risquer d être empoisonné au monoxyde de carbone CO ce qui pourrait entraîner des conséquences grave ou la mort POUR COUPER L ALIMENTATION EN GAZ DE L APPAREIL 1 Pour arrêter le brûleur mettre l interrupteur à la position OFF ou ajustez le thermostat à une ...

Page 28: ...2 000 FT 0 610 M 35 000 23 000 35 000 23 500 25 000 17 500 25 000 18 000 MANIFOLD PRESSURE IN WC 3 5 10 0 3 5 10 0 MIN INLET PRESSURE IN WC 5 0 11 5 0 11 ORIFICE DMS 0 2 000 FT 0 610 M 34 111 IN 50 070 IN 42 093 IN 53 059 IN UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS DATE OF MANUFACTURE DATE DE FABRICATION 2007 2009 201...

Page 29: ...out your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 877 247 3673 Replacement parts See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox Hearth Products distributor or dealer Parts...

Page 30: ... 2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...

Reviews: