NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Insert Dimensions

Minimum Fireplace Cavity

Top View

Side View

A

B

C

D

Figure 1

Figure 2

Figure 3

31-1/4”(794mm)

7-1/4”

(184mm)

2-1/2”

(64mm)

15-3/4”

(400mm)

Air Intake

Flue

13”

(330mm)

14-1/2”

(368mm)

16”(406mm)

17-1/4”

(438mm)

7-1/2”

(191mm)

15-1/4”

(387mm)

       CAUTIONS 

 

Trim panels or surrounds must not seal ventila-

tion openings in the existing fireplace that the 

appliance is installed in.

 

The fireplace in which this gas insert is to be 

installed must be thoroughly cleaned if it has 

been used to burn wood or synthetic logs. Have 

the chimney and all inside surfaces of the fire-

place brushed and vacuumed so that no soot, 

embers, or loose combustion deposits can be 

drawn into the heat circulation blower and blown 

into the living area. 

 

If any portion of the chimney system shows signs 

of structural or mechanical weaknesses, such 

as:  cracks,  leaky  joints,  corroded  or  warped 

surfaces,  the  faulty  portion  must  be  repaired 

or replaced prior to installing this appliance.

 

The factory built firebox must accept the insert 

without modification other than removing bolted 

or  screwed  together  pieces  such  as  baffles  / 

smoke shelf / deflectors, ash lips, glass door, 

screen or door tracks, log grates, refractory or 

masonry  lining  and  damper  assemblies.  Any 

fireplace component, which is removed, must be 

retained so they can be reinstalled to restore the 

fireplace to its original operating condition. The 

removal of any part must not alter the integrity 

of the outer shell of the pre-engineered fireplace 

cabinet in any way.  Any parts removed must be 

replaceable.  If any components are removed 

from  (or  altered)  from  the  existing  fireplace, 

a Warning Label (see Page 4) must be affixed 

inside the fireplace firebox, so that it shall be 

visible upon removal of the fireplace insert.  Note: 

RTV high temperature silicone is an approved 

adhesive to affix the label. 

Minimum Fireplace Opening Required

A  =  31-1/4” (794mm) Front Opening

B  =  17-1/4” (438mm) Height

C  =  19” (483mm) Rear Width**

D  =  16” (406mm) Fireplace Depth

*  Top air duct will need to be removed for short ZC applica-

tions. Replace tap tights when removed.

**This dimension is with the air duct hood removed (see 

Page 10

).

Insert Dimensions

Width of insert behind Surround Panels

31-1/4" (794mm)

Rear height

17-1/4" (438mm)

Insert depth into fireplace

15-3/4" (400mm)

Flue center line from back of surround with 45º 
collar

13-3/4" (349mm)

Flue collar diameter (OD)

-15/16" (75mm)

Summary of Contents for Merit Medina

Page 1: ...des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz WARNING If the information in this manual is not foll...

Page 2: ...lation Any modification or alteration may result in damage to the appliance or dwelling and will void the warranty certification and listings of this unit Failure to use manufacturer provided parts va...

Page 3: ...10 Surround Panels Installation 11 Face Installation 11 Gas Line Installation 12 Gas Pressure Requirements 12 LP and Natural Gas Supplies 12 Air Shutter Adjustment 12 13 Operating Instructions 13 16 P...

Page 4: ...le must be plugged with a non combustible insulation after the gas supply line has been installed The installer must mechanically attach the marking supplied with the gas fireplace insert to the insid...

Page 5: ...stallation of these fireplaces are approved for installation in New York City in the US state of New York MEA 138 07 E Commonwealth Of Massachusetts Require ments Massachusetts Approval G3 0806 6 Note...

Page 6: ...Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Installation and Operation Manual Decorative Face Kits One Required kit is shipped in 2...

Page 7: ...ed together pieces such as baffles smoke shelf deflectors ash lips glass door screen or door tracks log grates refractory or masonry lining and damper assemblies Any fireplacecomponent whichisremoved...

Page 8: ...imum clearances include any projections such as shelves window sills mantels spacers standoffs or surfaces to combustible construction etc above the ap pliance Paint or lacquer used to finish the mant...

Page 9: ...the vent manufacturer s instructions for installation and vent termination These appliances are approved for use with the following vent kits Vertical Cap Termination Connector Exhaust Intake Combust...

Page 10: ...anship like manner This access hole must be plugged with a non combustible insulation after the gas supply line has been installed The installermustmechanicallyattachthemarkingsupplied with the gas fi...

Page 11: ...ation The faces come with hooked brackets To install the face hang the hooked brackets on the surround brackets per instructions provided in decorative face kit C in Figure 12 Figure 12 A B C Spring H...

Page 12: ...iance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig The appliance must be...

Page 13: ...ighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Page 14: ...or thermostat if installed to its lowest setting 2 Turn off electric power to the appliance if service is to be performed 3 Push in gas control knob slightly and turn clockwise to OFF Do not force Th...

Page 15: ...flowofgasthroughthe gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat...

Page 16: ...e to determine the proper gage of wire for the thermostat or wall switch connections This table refers to the total length of the wire out to the switch and back The thermostat must be a millivolt typ...

Page 17: ...and extend across the main burner ports Be careful not to back the screw out of its threads Replace the cover and check for gas leaks using a gas leak test solution oCheck that the area around the in...

Page 18: ...ow for ref erence Remove the insert face glass door and log set All of these items are fragile so handle them with care Next remove the nine allen head screws around the outside of the panel fastened...

Page 19: ...f pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot shoul...

Page 20: ...ner LP 53 H5951 Orifice High Altitude Main Burner LP 54 H5464 Conversion Kit NG to LP H5465 Conversion Kit LP to NG H6013 Blower w Mounting Bracket H5875 Blower Snap Switch H5655 Blower Speed Control...

Page 21: ...Deluxe Thermostat DC H4635 Wall Thermostat Digital 75273 Round Black On Off Switch Cover Plate Finish Panels Front Supports 75264 ZC Lower Finish Panel Trad Face Support Requires Trim Piece below 7525...

Page 22: ...ase de H l appareil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FO...

Page 23: ...teur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde d...

Page 24: ...tain this manual File it with your other documents for future refer ence Product reference information Werecommendthatyourecordthefollowingimportantinformationabout your appliance Please contact your...

Reviews: