31
Table 2. Alert Codes and Troubleshooting
GF= Gas Furnace, AH=Air Handler, ID=Indoor unit (GF or AH), HP=Heat Pump, AC=Air Conditioner, OD=Outdoor Unit (AC or HP), PA=Pure Air S, ZA=Zone system and TS=Thermostat
Alert
Code
Inverter
Flash
Code
Priority
Condition
Actual Displayed
Alert Text
Under dealer
control center >
Notifications
Component or System Operational State and Troubleshooting Tip
How to clear alert code
428
22
Service
Soon/Service
Urgent
OD Inverter
High Main Input
Current
The inverter has detected a high main input current condition
.
• If condition is detected, outdoor unit will stop (compressor and fan) – service soon condition.
• Anti-short cycle is initiated.
•
If condition occurs 10 times within an hour, system will lockout – service urgent condition.
•
Inverter LEDs will flash code 22.
• Refer to the unit service documentation for detailed troubleshooting procedures.
Inverter flash code 22.
The sequence is:
•
Red LED: Two Flashes
•
Green LED: Two Flashes
NOTE:
Inverter normal operations with no error code present is as follows. Red LED is ON and
Green LED is OFF.
To clear, disconnect power to outdoor unit
and restart.