507581-05
Page 21 of 62
Issue 2220
Maximum Allowable Exhaust Vent Lengths with Furnace Installed in a Closet or Basement Using Ventilated
Attic or Crawl Space for Intake Air in Feet
Standard Termination at Elevation 0 - 4,500 ft
Number
of 90°
Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
Model
030
045
70
90
110
030
045
70
90
110
030
045
70
90
110
030
045
70
90
110
1
20
15
n/a
n/a
66
51
29
9
95
95
73
38
113
112
93
93
2
15
10
61
46
24
4
90
90
68
33
108
107
88
88
3
10
n/a
56
41
19
n/a
85
85
63
28
103
102
83
83
4
n/a
51
36
14
80
80
58
23
98
97
78
78
5
46
31
9
75
75
53
18
93
92
73
73
6
41
26
4
70
70
48
13
88
87
68
68
7
36
21
n/a
65
65
43
8
83
82
63
63
8
31
16
60
60
38
3
78
77
58
58
9
26
11
55
55
33
n/a
73
72
53
53
10
21
6
50
50
28
68
67
48
48
Standard Termination Elevation 4,501 - 10,000 ft
Number
of 90°
Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
Model
030
045
70
90
110
030
045
70
90
110
030
045
70
90
110
030
045
70
90
110
1
20
15
n/a
n/a
66
51
29
n/a
95
95
73
38
113
112
93
93
2
15
10
61
46
24
90
90
68
33
108
107
88
88
3
10
n/a
56
41
19
85
85
63
28
103
102
83
83
4
n/a
51
36
14
80
80
58
23
98
97
78
78
5
46
31
9
75
75
53
18
93
92
73
73
6
41
26
4
70
70
48
13
88
87
68
68
7
36
21
n/a
65
65
43
8
83
82
63
63
8
31
16
60
60
38
3
78
77
58
58
9
26
11
55
55
33
n/a
73
72
53
53
10
21
6
50
50
28
68
67
48
48
NOTE
: Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length
calculation.
Table 5C.