Start-Up & Operation Information

NOTE - 

When the furnace is not in operation the diagnostic

LED will display a “slow flash” - 1 second on 1 second off.
On a call for heat demand and normal heating operation
the diagnostic RED LED will display a “continuous rapid
flash”. The RED LED can be seen through the viewport on
the lower access panel. See figure 2.

WARNING

If you do not follow these instructions exactly, a fire
or explosion may result causing property damage,
personal injury or death.

BEFORE PLACING THE UNIT INTO OPERATION,

 smell

all around the appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than air and will
settle on the floor.

The gas valve on the EL195UHNE will be equipped with a
gas control switch. Use only your hand to move the
switch. Never use tools. If the switch will not move by
hand, do not try to repair it. Call a licensed professional
service technician (or equivalent). Force or attempted re­
pair may result in a fire or explosion.

FIGURE 2

Furnace Integrated Control

RED LED

Placing the EL195UHNE furnace into operation:

EL195UHNE units are equipped with an ignition system.
Do not attempt to manually light burners on this furnace.
Each time the thermostat calls for heat, the burners will
automatically light. The ignitor does not get hot when
there is no call for heat on units with this ignition system.

Operating the Gas Valve (Figure 3)

 1 -

STOP

! Read the safety information at the beginning of

this section.

 2 - Set the thermostat to the lowest setting.

 3 - Turn off all electrical power to the unit.

 4 - This furnace is equipped with an ignition device which

automatically lights the burners. Do 

not

 try to light the

burners by hand.

 5 - Remove the access panel.

 6 - Move switch on gas valve to 

OFF

. See figure 3.

 7 - Wait five minutes to clear out any gas. If you then smell

gas, 

STOP

! Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's instruc­
tions. If you do not smell gas go to next step.

 8 - Move switch on gas valve to 

ON

. See figure 3.

GAS VALVE SHOWN IN ON POSITION

FIGURE 3

 9 - Replace the access panel.

10 - Turn on all electrical power to to the unit.

11 - Set the thermostat to desired setting.

NOTE -

 When unit is initially started, steps 1 through 11

may need to be repeated to purge air from gas line.

12 - If the appliance will not operate, follow the section

“Turning Off Gas to the Unit” and call your licensed
professional service technician (or equivalent).

Turning Off Gas to the Unit

WARNING

If overheating occurs or if gas supply fails to shut off,
shut off the manual gas valve to the furnace before
shutting off electrical supply.

 1 - Set the thermostat to the lowest setting.

 2 - Turn off all electrical power to the unit if service is to be

performed.

 3 - Remove the upper access panel.

 4 - Move switch on gas valve 

OFF

.

 5 - Replace the upper access panel.

WARNING

Do not set thermostat below 60°F (16°C) in heating
mode. Setting thermostat below 60°F (16°C) reduces
the number of heating cycles. Damage to the unit
may occur that is not covered by the warranty.

Summary of Contents for EL195UHNE Series

Page 1: ...t use any phone in your building D Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions D If you cannot reach your gas supplier call the fire department D Leave the building immediately GAS FURNACE FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exact ly could result in serious injury death or property damage WARNING Improper installation adj...

Page 2: ...ith the equipment user Notice to Homeowner This furnace is equipped with safety devices that protect you and your property If one or more of these devices is activated furnace operation will stop If your home is left unattended for an extended period of time equipment op eration must be checked periodically If this is not possible the water supply to the house should be shut off and the pipes shou...

Page 3: ...y the furnace duct system WARNING The blower door must be securely in place when the blower and burners are operating Gas fumes which could contain carbon monoxide can be drawn into the living space resulting in personal injury or death Your furnace is a gas appliance It is critical that the gas supplied to the unit be completely burned to avoid the pro duction of carbon monoxide gas Complete comb...

Page 4: ...he safety information at the beginning of this section 2 Set the thermostat to the lowest setting 3 Turn off all electrical power to the unit 4 This furnace is equipped with an ignition device which automatically lights the burners Do not try to light the burners by hand 5 Remove the access panel 6 Move switch on gas valve to OFF See figure 3 7 Wait five minutes to clear out any gas If you then sm...

Page 5: ...ious signs of deterioration Inspect the furnace venting system to make sure it is in place physically sound and without holes corrosion or blockage Vent pipe must be clear and free of obstructions and must slope upward away from the furnace Inspect the furnace return air duct connection to ensure duct is sealed to the furnace and terminates outside the space containing the furnace Inspect the phys...

Page 6: ...arings if ap plicable 3 Inspect all gas pipe and connections for leaks 4 Check the cleanliness of filters and change if necessary monthly 5 Check the condition and cleanliness of burners and heat exchanger and clean if necessary 6 Check the cleanliness of blower assembly and clean the housing blower wheel and blower motor if neces sary 7 Inspect the condensate drain and trap for leaks and cracks T...

Page 7: ...ressure ad justment is necessary consult the Service Literature for unit specific information on adjusting gas pressure Not all gas valves are adjustable Verify correct tem perature rise CAUTION As with any mechanical equipment personal injury can result from contact with sharp sheet metal edges Be careful when you handle this equipment Repair Parts List The following repair parts are available th...

Reviews: