background image

EL296UHV

SERIES

Litho U.S.A.

506769-01
10/2015
Supersedes 02/2015

E

 2015 Lennox Industries Inc.

Dallas, Texas, USA

WHAT TO DO IF YOU SMELL GAS:

Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other ap­
pliance.

Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.

D

Do not try to light any appliance.

D

Do not touch any electrical switch; do not
use any phone in your building.

D

Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.

D

If you cannot reach your gas supplier, call
the fire department.

D

Leave the building immediately.

GAS FURNACE

FIRE OR EXPLOSION HAZARD.

Failure to follow safety warnings exact­
ly could result in serious injury, death,
or property damage.

WARNING

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), a service agency, or the gas supplier.

WARNING

Summary of Contents for EL296UHV series

Page 1: ...use any phone in your building D Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions D If you cannot reach your gas supplier call the fire department D Le...

Page 2: ...e left with the equipment user Notice to Homeowner This furnace is equipped with safety devices that protect you and your property If one or more of these devices is activated furnace operation will s...

Page 3: ...in personal injury or death Your furnace is a gas appliance It is critical that the gas supplied to the unit be completely burned to avoid the pro duction of carbon monoxide gas Complete combustion o...

Page 4: ...o to the unit 11 Set the thermostat to desired setting NOTE When unit is initially started steps 1 through 11 may need to be repeated to purge air from gas line 12 If the appliance will not operate fo...

Page 5: ...e drain and trap must also be cleaned and the trap must be filled with water During a seasonal check the service technician will con duct a combustion analysis The technician will also in spect the in...

Page 6: ...ap plicable 3 Inspect all gas pipe and connections for leaks 4 Check the cleanliness of filters and change if necessary monthly 5 Check the condition and cleanliness of burners and heat exchanger and...

Page 7: ...ot all gas valves are adjustable Verify correct tem perature rise WARNING Sharp edges Be careful when handling unit to avoid sharp edges which may result in personal injury Repair Parts List The follo...

Reviews: