Safety Instructions
Lennox G32V units are Category IV CSA International
certified to ANSI Z21.47 and CSA 2.3 standards.
In the USA, installation of Lennox gas central furnaces
must conform with local building codes. In the absence of
local codes, units must be installed according to the curĆ
rent National Fuel Gas Code (ANSI-Z223.1/NFPA 54) in
the United States. The National Fuel Gas Code is availĆ
able from the following address:
American National Standards Institute, Inc.
11 West 42nd Street
New York, NY 10036
In Canada, installation must conform with current NationĆ
al Standard of Canada CAN/CGAĆB149.1 Installation
Code for Natural Gas Burning Appliances and EquipĆ
ment" and CAN/CGA-B149.2 Installation Code for ProĆ
pane Gas Burning Appliances and Equipment," local
plumbing or waste water codes and other applicable local
codes.
This furnace is CSA International certified for installation
clearances to combustible material as listed on the unit
rating plate and in table 1.
TABLE 1
Clearances
Location
Inches (mm)
Front
24 (610)
Service access
Condensate side
3 (76)
(from side of unit)
Top
1 (25)
To combustible
Exhaust
0
To combustible
materials
Side, rear, and front
0
Floor
0
NOTE - For installation on combustible floors, the furnace
shall not be installed directly on carpeting, tile, or other
combustible material other than wood flooring.
Accessibility and service clearances must take preceĆ
dence over fire protection clearances.
For installation in a residential garage, the furnace must
be installed so that the burner(s) and the ignition source
are located no less than 18 inches (457 mm) above the
floor. The furnace must be located or protected to avoid
physical damage by vehicles. When a furnace is installed
in a public garage, hangar, or other building that has a
hazardous atmosphere, the furnace must be installed acĆ
cording to recommended good practice requirements
and current National Fuel Gas Code or CAN/CGA B149.1
and B149.2 standards.
When the furnace is used with cooling units, it shall be
installed in parallel with, or on the upstream side of, cool-
ing units to avoid condensation in the heating compartĆ
ment. With a parallel flow arrangement, a damper (or othĆ
er means to control the flow of air) must adequately
prevent chilled air from entering the furnace. If the dampĆ
er is manually operated, it must be equipped to prevent
operation of either the heating or the cooling unit, unless it
is in the full HEAT" or COOL" setting.
When installed, the furnace must be electrically grounded
according to local codes. In addition, in the United States,
installation must conform with the current National ElecĆ
tric Code, ANSI/NFPA No. 70. The National Electric Code
(ANSI/NFPA No. 70) is available from the following adĆ
dress:
National Fire Protection Association
1 Battery March Park
Quincy, MA 02269
In Canada, all electrical wiring and grounding for the unit
must be installed according to the current regulations of
the Canadian Electrical Code Part I (CSA Standard
C22.1) and/or local codes.
Field wiring connections must meet or exceed specificaĆ
tions of type T wire and withstand a maximum temperaĆ
ture rise of 180°F (82°C).
G32V unit must be installed so that electrical components
are protected from water.
When the furnace is installed so that supply ducts carry
air circulated by the furnace to areas outside of the space
containing the furnace, return air shall be handled by a
duct(s) sealed to the furnace casing and terminating outĆ
side space containing furnace.
WARNING
Product contains fiberglass wool.
Disturbing the insulation in this product during
installation, maintenance, or repair will expose you
to fiberglass wool dust. Breathing this may cause
lung cancer. (Fiberglass wool is known to the State
of California to cause cancer.)
Fiberglass wool may also cause respiratory, skin,
and eye irritation.
To reduce exposure to this substance or for further
information, consult material safety data sheets
available from address shown below, or contact
your supervisor.
Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379-9900