Page 3
SPECIFICATIONS
Gas
H
ti
ModelNo.
G41UF−60C−090
G41UF−48C−110
G41UF−60C−110
G41UF−60D−135
Heating
Performance
Input− Btuh (kW)
88,000 (25.8)
110,000 (32.2)
110,000 (32.2)
132,000 (38.7)
Performance
Output− Btuh (kW)
80,000 (23.4)
100,000 (29.3)
100,000 (29.3)
120,000 (35.1)
1
AFUE
90.0%
90.0%
90.0%
90.0%
Highstatic(CSA)− in.w.g. (Pa)
0.5
0.5
0.5
0.5
Temperature rise range −
_
F (
_
C)
25 − 55 (14 − 31)
50 − 80 (28 − 44)
40 − 70 (22 − 39)
45 − 75 (25 − 42)
Connections
in (mm)
Exhaust Pipe (PVC)
2 (51)
2 (51)
2 (51)
2 (51)
in. (mm)
Condensate Drain (PVC Pipe) − i.d.
1/2 (13)
1/2 (13)
1/2 (13)
1/2 (13)
Condensate Drain (PVC Coupling) − o.d.
3/4 (19)
3/4 (19)
3/4 (19)
3/4 (19)
GaspipesizeIPS
1/2 (13)
1/2 (13)
1/2 (13)
1/2 (13)
Indoor
Blower
Wheelnominaldiameter xwidth −in. (mm) 11−1/2 x 10 (292 x 229)
10 x 10 (254 x
254)
11−1/2 x 10 (292 x
229)
11−1/2 x 10 (292 x
229)
Motoroutput − hp (W)
3/4 (560)
1/2 (373)
3/4 (560)
3/4 (560)
Tons(kW) ofaddoncooling
4 − 5 (14.0 − 17.5)
2 − 4 (7.0 − 14.0)
4 − 5 (14.0 − 17.5)
4 − 5 (14.0 − 17.5)
Shippingweight − 1 package
168 lbs. (76 kg)
173 lbs. (78 kg)
177 lbs. (80 kg)
194 lbs. (88 kg)
Electricalcharacteristics
120 volts − 60 hertz − 1 phase (less than 12 amps)
OPTIONAL ACCESSORIES – MUST BE ORDERED EXTRA
4,6
Air Filter and Rack Kit − Number & size of filters
Single
44J22
or Ten Pack
66K63 −
(1) 16 x 25 x 1 (406 x 635 x 25)
EZ Filter
Base
Catalog Number − Shipping Weight
73P57
− 8 lbs. (4 kg)
73P58
− 10 lbs. (5 kg)
Base
Dimensions − H x W x D 4 x 21−5/8 x 28−5/8 in. (102 x 549 x 727 mm)
4 x 24−5/8 x 28−5/8 in. (102 x 625 x 727 mm)
Number and size of field provided filter
20 x 25 x 1 in. (508 x 635 x 25 mm)
24 x 24 x 1 in. (610 x 610 x 25 mm)
Condensate
Drain Heat
6 ft. (1.8 m) long
26K68
26K68
26K68
26K68
Drain Heat
Cable
24 ft. (7.3 m) long
26K69
26K69
26K69
26K69
50 ft. (15.2 m) long
26K70
26K70
26K70
26K70
Heat Cable
Tape
Fiberglass − 1/2 in. (38 mm) x 66 ft. (20 m)
39G04
39G04
39G04
39G04
Tape
Aluminum foil − 2 in. (25 mm) x 60 ft. (18 m)
39G03
39G03
39G03
39G03
7
High Altitude Orifice Kit −
Natural Gas Only
47M82
47M82
47M82
47M82
3
High Altitude
Pressure Switch Kit
4501−7500 ft. (1372−2286 m)
46M94
46M94
46M94
− − −
Pressure Switch Kit
7501−10,000 ft. (2286−3048m)
46M94
46M94
46M94
46M95
RAB Return Air Base
RAB60C (
12M71
)
− − − −
RAB60D (
12M72
)
RAB60D (
12M72
)
LPG/Propane Kit
0−7500 ft. (0−2286 m)
47M83
47M83
47M83
47M83
7501−10,000ft. (2286−3048m)
47M81
47M81
47M81
47M81
5
Termination
Kits
Roof − 2 inch (51 mm)
15F75
15F75
15F75
15F75
Kits
Roof − 3 inch (76 mm)
44J41
44J41
44J41
44J41
Wall Ring − 2 inch (51 mm)
15F74
15F74
15F74
15F74
Twinning Kit
15L38
15L38
15L38
15L38
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for nonweatherized
furnaces.
3
Required for proper operation at altitudes over 4500 ft. (1370 m).
4
Cleanable polyurethane frame type filter.
5
Kits contain enough parts for two installations. Determine from venting tables proper exhaust pipe size and termination kit required.
6
Not for use with RAB Return Air Base or with 60C and 60D size units with air flow requirements of 1800 cfm (850 L/s) or greater. See Blower Performance
tables for additional information.
7
Required for proper operation at altitudes from 7501 to 10,000 ft. (2286 to 3048 m).
NOTE − Filters and provisions for mounting are not furnished and must be field provided.