icomfort Touch
7−Day Programmable Communicating Thermostat
Page 25
Table 3. Adjustable Parameters Table (User)
Parameter Name:
Default
Parameter Value Setting
Increment
Installer
entry
Time and Date*
(Time/date elements screen)
Daylight Saving
Time*
Enabled
Enabled, Disabled
Circulate Fan − Per-
centage of Time
ON*
35%
15 to 45%
1%
Dealer Contact In-
formation –
Name*
Lennox
(Typewriter input screen)
Address
(Typewriter input screen)
Phone
1−800−9−LEN-
NOX
(Typewriter input screen)
(Typewriter input screen)
Website
www.len-
nox.com
(Typewriter input screen)
Language Dis-
played
English
English
Temperature Dis-
play Scale
(F)
(F) Fahrenheit, (C) Celsius
Clock Format
12H
12 Hour, 24 Hour
Screen Lock−out
Unlocked
Unlocked, Partially Locked, Fully Locked
Backlight Setting
Always On
Power Save, Always On
Backlight Intensity
100%
20 to 100%
20%
Outdoor Temp Dis-
play
Disabled
Disabled, Enabled
Indoor Humidity Dis-
play
Enabled
Disabled, Enabled
Filter 1 Timer
Disabled
Disabled, 3 Months, 6 Months, 12 Months, 24 Months,
Custom Time
Filter 1 Timer
Disabled
Disabled, 3 Months, 6 Months, 12 Months, 24 Months,
Custom Time
Humidifier Pad Tim-
er
Disabled
Disabled, 3 Months, 6 Months, 12 Months, 24 Months,
Custom Time
UV Bulb Timer
Disabled
Disabled, 3 Months, 6 Months, 12 Months, 24 Months,
Custom Time
Maintenance Timer
Disabled
Disabled, 3 Months, 6 Months, 12 Months, 24 Months,
Custom Time
PureAir Timer
Disabled
Disabled, 3 Months, 6 Months, 12 Months, 24 Months,
Custom Time
* Entered during initial installer setup (during initial discovery); should be edited from user preferences.
THERMOSTAT (Go to EQUIPMENT tab and scroll to THERMOSTAT 49W95.)
NOTE − These settings apply to the thermostat’s internal sensors.
Equipment Name
(Typewriter input screen)
Temp Reading Cal-
ibration
0ºF
−5ºF to 5ºF
1ºF
Humidity Reading
Calibration
0%
−10 to 10%
1%RH