iComfort
Wi‐Fi
®
7-Day Programmable Communicating Thermostat
3
This thermostat supports:
Wireless bands 802.11b, 802.11g and 802.11n
Three languages (English, French, Spanish)
Air conditioning or heat pump units with up to four stages of heat / two
stages of compressor operation (2 stages of heat pump heating, 2
stages of auxiliary back-up heating and 2 stages of emergency
heating)
Variable-capacity / multiple-stage heat / cool and universal
compatibility (gas/electric/heat pump/air conditioner).
Dual-fuel capable (iComfort®-enabled HP only) with two balance
points.
Indoor air quality with time‐based notification of consumables
including media filters, UVC bulbs, humidifier pads and PureAir
system catalyst service / replacement,
iHarmony
®
Zoning System (2 - 4 zones)
Lennox iComfort
®
Equipment Interface Module (Catalog number
10T50
)
(provides iComfort Wi-FI
®
to non-communicating indoor unit,
Humidification measurement and control.
Dew point adjustment control
Humiditrol
®
Enhanced Dehumidification Accessory (EDA)
Multiple-stage HVAC systems
Equipment maintenance reminders
Autochangeover mode -- Permits control of heating, cooling,
humidification, and dehumidification without user involvement
All Lennox branded communicating outdoor units contain a built-in
outdoor temperature sensor.
Installation and Setup
During initial thermostat start-up the following screen will appear (see figure
1). This indicates that the thermostat is active and booting up.
...
Figure 1. Boot-Up Screen
COMMUNICATION ERROR SCREEN
During initial thermostat start-up if the following screen appears (see figure
2), this will indicate that the thermostat has been incorrectly wired or has
shorted wires. Turn power off to the system and verify that all wiring is
correct.
Figure 2. Communication Error Screen