Page 24
Wiring Diagrams – LRP14AC / LRP14HP
Figure 12. Connections Diagram - A/C Constant Torque
208/230-1-60
POWER SUPPLY WITH MIN.
75C
COPPER
WIRE
BLK
RED
YEL
RED
T2
L2
C
H
F
WHT
BLK
BRN
PUR
RED
RED
BLK
208V
240V
INDOOR BLOWER MOTOR
REDUCE
TO 6.00
REDUCE TO 10.00
REDUCE
TO
BLU
YEL
CAPACITOR
H
M
L
C
NO
NC
C
P-3
BLOWER CONTROL
NC
C
BLK
C
G
XFMR-R
R
XFMR-C
W1
C
L
R
O
Y1
FAN
O-OUT
LO-PS
DF
HI-PS
COMMON
Y1 OUT
2
2
24 V
Y
W2
RED
YEL
BLU
WHT
GRN
ORN
RED
BLU
BLU
YEL
BLU
2
W1 & W2 CAN BE USED TO STAGE ELECTRIC HEAT ACCESSORY ON 15 & 20KW MODELS
5, 7.5 & 10KW HEATER ACCESSORIES FUNCTION OFF W1 ONLY.
BLK
BLK
DEFROST CONTROL
BLU
WHT
DEFROST CONTROL
P-2
P-4
P-6
P-5
LOW PRESSURE
SWITCH (IF USED)
G
W1
C
R
YEL W/ STRIPE
CONTROL CIRCUIT WIRING TO BE 24 VOLT, N.E.C. CLASS 2
L1
T1
T2
L2
C
H
F
OUTDOOR FAN MOTOR
C12 DUAL CAPACITOR
COMPRESSOR
C
S
R
537663-01
GRY
RED
BLK
208V
240V
24V
INDOOR BLOWER MOTOR
NOTE: IF ANY OF THE ORIGINAL WIRE IS REPLACED THE SAME SIZE AND TYPE WIRE MUST BE USED. USE COPPER CONDUCTOR ONLY, MIN 75
C WIRE
LINE VOLTAGE FIELD INSTALLED
WARNING- ELECTRIC SHOCK HAZARD. UNIT MUST BE GROUNDED IN ACCORDANCE WITH NATIONAL AND LOCAL CODES.
YEL
Y
WHT
GRN
5 & 7.5KW HEATER ACCESSORIES FUNCTION OFF W1 ONLY.
BLK
J2-1
J2-2
BLK
C
1
2
3
4
5
J2-6
J2-5
WHT
BLU
RED
YEL
WHT
B1
PUR
B4
BLACK
ORG
L
N
G
B3
S1
TRANSFORMER TI
L
G
N
BLK
K1-1 CONTACTOR
YEL W/ STRIPE
CONTACTOR
K1-2
BLU
BLU
GRN
CONTACTOR KI
YEL
BLK
J2-4
NOTE: TAP1 FOR FAN ONLY TAP 2 FOR COOLING TAP3 FOR HIGH STATIC COOLING TAP4 AND TAP5 FOR ELECTRIC HEAT- REFER TO HEATING LABEL
BLK W/ STRIPE
YEL
THERMAL PROTECTION
SWITCH (IF USED)
208/230V-1-60
BLOWER SPEED CHART
UNIT
FACTORY SHIPPED SETTINGS
COOLING INPUT
(BLK)
24
LOW
30
MED
36
HIGH
42
LOW
48
MED
60
HIGH
G
W1
C
R
O
CONTACTOR
THERMOSTAT
HIGH PRESSURE
SWITCH (IF USED)
L1
T1
CONDENSER FAN MOTOR
COMPRESSOR CONTACTOR
COMPRESSOR CONTACTOR
DUAL CAPACITOR
COMPRESSOR
TRANSFORMER
C
S
R
L2
L1
537663-01
CONNECTION DIAGRAM, HEAT PUMP - PACKAGED
24V
NOTE: IF ANY OF THE ORIGINAL WIRE IS REPLACED THE SAME SIZE AND TYPE WIRE MUST BE USED. USE COPPER CONDUCTOR ONLY, MIN 75
C WIRE
CONNECTION MUST BE JUMPERED WHEN PRESSURE SWITCH IS NOT USED.
LINE VOLTAGE FIELD INSTALLED
WARNING- ELECTRIC SHOCK HAZARD. UNIT MUST BE GROUNDED IN ACCORDANCE WITH NATIONAL AND LOCAL CODES.
SEE CHART FOR WIRING
L M H C
MOTOR
SPEED TAPS
FUSE
BLOWER CONTROL
DIAGNOSTIC CODES FOR DEFROST CONTROL LEDS
Note: Because the Pressure Switches are monitored only when "Y1" (Input) is active, the code for pressure switch open will not be seen when "Y1" is off. Instead, the "Normal Operation" or "Anti Short Cycle" code will be seen. Also, when a pressure switch opens and caused a short cycle lockout, the pressure switch-open code will be seen until it closes, then the short cycle lockout code will flash unless it has already expired.
REV. VALVE
DEFROST T'STAT
P-1
(See instructions or markings on System Diagnostic Module for codes of System Diagnostic Module)
YEL
YEL
HIGH PRESSURE
SWITCH
LOW PRESSURE SWITCH (IF USED)
J1: PLUG THROUGH CONTROL PANEL (12 PIN) J2: PLUG FOR ACCESSORY HEAT (6 PIN)
INDOOR BLOWER MOTOR
B-3
J1-3
J1-1
J1-2
J1-12
S4
S79
S173
J1-11
CONNECTION DIAGRAM
A/C (CONSTANT TORQUE BLOWER)
SINGLE PHASE
THERMOSTAT
W1 & W2 CAN BE USED TO STAGE ELECTRIC HEAT ACCESSORY ON 10, 15 & 20KW MODELS
CRANK CASE HEATER (IF USED)
BLK
BLK
HR1
Description
DS2 (GREEN)
DS1 (RED)
No Power to Control
OFF
OFF
Normal Operation / Power to
Control
Simultaneous Slow Flash
Anti-Short Cycle Lockout
Alternate Slow Flash
Low Pressure Switch Fault
OFF
Slow Flash
Low Pressure Switch Lockout
OFF
ON
High Pressure Switch Fault
Slow Flash
OFF
High Pressure Switch Lockout
ON
OFF