Page 2
SPECIFICATIONS
Gas
Heating
Performance
Model No.
ML180DF045E36A
ML180DF070E36A
ML180DF070E36B
1
AFUE
80%
80%
80%
Input - Btuh
44,000
66,000
66,000
Output - Btuh
36,000
54,000
54,000
Temperature rise range - °F
15 - 45
30 - 60
30 - 60
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
High Static - in. w.g.
0.50
0.50
0.50
Connections
in.
Flue connection - in. round
4
4
4
Gas pipe size IPS
1/2
1/2
1/2
Indoor
Blower
Wheel nom. dia. x width - in.
10 x 8
10 x 10
10 x 10
Motor Type
DC Brushless
DC Brushless
DC Brushless
Motor output - hp
1/2
1/2
1/2
Tons of add-on cooling
1.5 - 3
1.5 - 3
1.5 - 3
Air Volume Range - cfm
355 - 1430
675 - 1460
430 - 1475
Electrical Data
Voltage
120 volts - 60 hertz - 1 phase
Blower motor full load amps
6.8
6.8
6.8
Maximum overcurrent protection
15
15
15
Shipping Data
lbs. - 1 package
113
119
128
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
SPECIFICATIONS
Gas
Heating
Performance
Model No.
ML180DF090E48B
ML180DF110E60C
1
AFUE
80%
80%
Input - Btuh
88,000
110,000
Output - Btuh
72,000
90,000
Temperature rise range - °F
30 - 60
30 - 60
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0
3.5 / 10.0
High Static - in. w.g.
0.50
0.50
Connections
in.
Flue connection - in. round
4
4
Gas pipe size IPS
1/2
1/2
Indoor
Blower
Wheel nom. dia. x width - in.
10 x 10
11-1/2 x 10
Motor Type
DC Brushless
DC Brushless
Motor output - hp
3/4
1
Tons of add-on cooling
2.5 - 4
3 - 5
Air Volume Range - cfm
680 - 1750
990 - 2410
Electrical Data
Voltage
120 volts - 60 hertz - 1 phase
Blower motor full load amps
8.4
10.9
Maximum overcurrent protection
15
15
Shipping Data
lbs. - 1 package
140
160
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.