BLOWER DATA
ML296UH045XV36B BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
“ADJUST”
Switch
Positions
Speed Switch Positions
Second Stage “HEAT” Speed - cfm
Second Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
780
880
990
1010
920
1065
1205
1340
1
NORM
705
795
905
925
815
985
1110
1245
—
640
715
805
810
745
890
1020
1130
“ADJUST”
Switch
Positions
First Stage “HEAT” Speed - cfm
First Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
705
795
905
925
610
760
845
975
1
NORM
645
725
810
815
550
680
770
880
—
570
655
735
750
465
610
720
775
1
Factory default jumper setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two-stage air conditioning units only) is approximately
70%
of the same second stage COOL speed
position.
Continuous Fan Only speed is approximately
38
%
of the same second stage COOL speed position - minimum
500 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 453 cfm.
BLOWER DATA
ML296UH070XV36B BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
“ADJUST”
Switch
Positions
Speed Switch Positions
Second Stage “HEAT” Speed - cfm
Second Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
965
1130
1255
1400
860
1060
1215
1365
1
NORM
880
990
1140
1295
810
960
1130
1265
—
810
890
1030
1170
705
840
1005
1140
“ADJUST”
Switch
Positions
First Stage “HEAT” Speed - cfm
First Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
940
1070
1195
1345
600
740
840
970
1
NORM
830
965
1100
1235
555
665
770
855
—
755
840
975
1130
500
600
680
790
1
Factory default jumper setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two-stage air conditioning units only) is approximately
70%
of the same second stage COOL speed
position.
Continuous Fan Only speed is approximately
38
%
of the same second stage COOL speed position - minimum
500 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 453 cfm.