Page 5
BLOWER DATA
ML296UH070XV36B BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
“ADJUST”
Switch
Positions
Speed Switch Positions
Second Stage “HEAT” Speed - cfm
Second Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
980
1095
1225
1395
840
1050
1205
1355
1
NORM
855
1005
1120
1250
750
945
1130
1230
—
755
870
1020
1170
685
805
990
1110
“ADJUST”
Switch
Positions
First Stage “HEAT” Speed - cfm
First Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
920
1055
1205
1325
590
705
805
955
1
NORM
800
950
1075
1215
540
640
725
820
—
730
810
960
1095
500
580
665
720
1
Factory default jumper setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two-stage air conditioning units only) is approximately
70%
of the same second stage COOL speed
position.
Continuous Fan Only speed is approximately
38
%
of the same second stage COOL speed position - minimum
500 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 453 cfm.
BLOWER DATA
ML296UH070XV36B BLOWER PERFORMANCE (less filter)
SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
“ADJUST”
Switch
Positions
Speed Switch Positions
Second Stage “HEAT” Speed - cfm
Second Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
975
1095
1245
1385
855
1045
1205
1350
1
NORM
870
995
1130
1280
790
945
1090
1255
—
790
885
1010
1155
720
845
985
1130
“ADJUST”
Switch
Positions
First Stage “HEAT” Speed - cfm
First Stage “COOL” Speed - cfm
D
1
C
B
A
D
C
B
1
A
+
925
1050
1175
1330
595
715
815
950
1
NORM
810
945
1070
1220
520
655
755
840
—
730
840
955
1095
490
595
670
745
1
Factory default jumper setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two-stage air conditioning units only) is approximately
70%
of the same second stage COOL speed
position.
Continuous Fan Only speed is approximately
38
%
of the same second stage COOL speed position - minimum
500 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 453 cfm.