background image

4

Important Operating Instructions

IMPORTANT

To ensure comfort, make sure that temperature selection has been
properly set at the remote control.
To ensure efficient operation, do not block air intake or outlet at either
the indoor or outdoor unit.
Do not stand on outdoor unit or store items on top of unit.
Make sure that indoor unit directional louver is properly adjusted.

System Operation

Cooling Operation

In the cooling mode, the indoor coil absorbs the
heat from the room and transfers it to the outdoor
coil where it is discharged. The system cooling
capacity is affected by the outdoor ambient tem-
perature. The indoor fan operates continuously in
the COOL mode. The indoor unit directional lou-
ver is fixed in an upward position.

If the unit is in the cooling mode, frost will form on
the indoor coil when the outdoor ambient temper-
ature reaches approximately 32°F (0°C). Typical-
ly, when the outdoor ambient temperature falls
below 32°F (0°C), the indoor unit control locks out
operation to protect the system.

In cooling mode, the operating range of the out-
door unit is typically from 41°F (5°C) to 115°F
(46°C).

Heating Operation

The refrigerant flow is reversed during the heating
cycle. In this case, the outdoor coil absorbs the
heat from outside and transfers it to the indoor coil
where it is discharged into the room. The system
heating capacity is also limited by the available
heat in the outdoor ambient air.

In the HEAT mode, the indoor fan will remain OFF
for two minutes in the following instances:

  

 

at the beginning of each heating cycle,

  

 

after a defrost cycle has ended,

In the heating mode, the indoor blower will contin-
ue to operate for 60 seconds after the outdoor unit
has shut off. The indoor unit directional louver is
fixed in a downward position.

In climates with very low winter temperatures, it
may be necessary to supplement heating by addi-
tional means (space heater, fireplace, etc.).

In heating mode, the operating range of the out-
door unit is typically from 05°F (−15°C) to 86°F
(30°C).

AUTO Mode Operation

When the system is set to operate in AUTO mode,
the indoor and outdoor units work together to
meet a series of preset demands. The remote
control temperature setpoint and fan operation
functions are not adjustable in the AUTO mode.

In AUTO mode, if the indoor ambient temperature
is greater than 77°F (25°C), the unit will operate
in the cooling mode. The outdoor unit will run until
the indoor ambient temperature reaches 75°F
(24°C). At this point, the outdoor unit compressor
and outdoor fan will operate for another 60 sec-
onds, then they will both turn off. The indoor fan
will run continuously at a speed determined by the
indoor ambient temperature. During AUTO cool-
ing operation, the indoor unit directional louver is
fixed in an upward position.

Heat Pump Systems Only

 −− In AUTO mode, if the

indoor ambient temperature is less than 68°F
(20°C), the unit will run in heating mode. The out-
door unit will run until the indoor ambient temper-
ature reaches 69°F (21°C). At this point, the out-
door unit compressor and fan will operate for
another 60 seconds, then they will both turn off.
The indoor fan will run continuously at a speed
determined by the indoor ambient temperature.
During AUTO heating operation, the indoor unit
directional louver is fixed in a downward position.

FAN Mode Operation

When the system is set to operate in FAN mode,
the indoor fan runs continuously in AUTO, low,
medium or high speed. The outdoor unit is off. In
AUTO fan mode, the fan speed is determined by
the indoor ambient air temperature.

DEHUMIDIFICATION Mode Operation

When the system is set to operate in DEHUMID-
IFICATION mode, the indoor fan runs continu-
ously in low speed.

Summary of Contents for MS7

Page 1: ...is manual is the property of the homeowner and must be left with the user 2011 Lennox Industries Inc Dallas Texas USA MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps 506789 01 08 201...

Page 2: ...perty damage personal injury or death For your safety and to fulfill the terms of the limited warranty a licensed professional service technician or equivalent must annually inspect this system This u...

Page 3: ...Tape e p i p n o i t c e n n o C Air inlet Typical indoor unit shown Actual unit may be slightly different Front Panel Display Air outlet Filter Directional Louver Wireless remote control Temperature...

Page 4: ...s fixed in a downward position In climates with very low winter temperatures it may be necessary to supplement heating by addi tional means space heater fireplace etc In heating mode the operating ran...

Page 5: ...mode and again for HEAT mode heat pumps only Selected mode is displayed on both remote and indoor unit cover panel buttons Use plus and minus buttons to adjust the temper ature setting up and down NOT...

Page 6: ...button to initi ate or cancel high speed fan operation to accelerate cooling or heating of the ambient room temperature The turbo icon is displayed when the function is turned on TEMP button Use the T...

Page 7: ...with the word ON flashing at the right Use the and keys to adjust the time setting to the desired time for the system to begin operation Press the TIMER ON button again to accept the setting When succ...

Page 8: ...speed will be set to low if DEHUMIDIFICATION mode has been selected 5 Press OSCILLATE button Indoor unit directional louver will open and begin to oscillate If a single setting is preferred press but...

Page 9: ...should not be placed in a drawer Make sure that there are no obstructions between the indoor unit receiver and the remote control Remote should remain within its receiving range to ensure proper syst...

Page 10: ...o make sure that there are no objects on top of unit or around unit that may be ob structing air flow Check to make sure that indoor unit and wall bracket are secure and have not been damaged Use a cl...

Page 11: ...oil when the outdoor unit starts or stops operation This is not a malfunction Mist is coming out of the indoor unit during cooling operation This sometimes happens when the indoor temper ature and hum...

Page 12: ...unit When this happens the unit will enter a defrost cycle The indoor fan is off during the 3 12 minute cycle In DEHUMIDIFICATION mode indoor fan opera tion may be stopped to avoid delivery of moist a...

Reviews: