IOM / ROOF-TOP FLEXY™ Series - Page 5
TRANSPORT - HANDLING
DIMENSIONS AND WEIGHTS
Condensation
Airflow configuration
WEIGHT (kg)
SLING
std
std
high
Standard
Centrifugal
1
2
3
4
5
6
7
8
gas
gas
1
2
3
FC/FH 060 - Cooling only and heat pump
X
-
X
-
-
-
-
-
-
X
2825
2255
1470
630
1060
-
-
2210
-
-
X
-
-
-
-
X
-
-
X
-
2825
2255
1470
630
1090
-
-
2210
-
-
X
-
-
X
X
-
X
X
-
-
2825
2285
1470
630
1090
-
-
2210
-
-
-
X
X
-
-
-
-
-
-
X
2875
2255
2070
630
1230
-
-
2590
1855
-
-
X
-
-
-
X
-
-
X
-
2875
2255
2070
630
1260
-
-
2590
1855
-
-
X
-
X
X
-
X
X
-
-
2875
2285
2070
630
1260
-
-
2590
1855
-
FG 060 - GAS
X
-
X
-
-
-
-
-
-
X
2825
2255
1470
630
-
1210
1280
2210
-
-
-
X
X
-
-
-
-
-
-
X
2875
2255
2070
630
-
1380
1450
2590
1855
-
FC/FH 070 - Cooling only and heat pump
X
-
X
-
-
-
-
-
-
X
2825
2255
1470
630
1075
-
-
2210
-
-
X
-
-
-
-
X
-
-
X
-
2825
2255
1470
630
1100
-
-
2210
-
-
X
-
-
X
X
-
X
X
-
-
2825
2285
1470
630
1100
-
-
2210
-
-
-
X
X
-
-
-
-
-
-
X
2875
2255
2070
630
1245
-
-
2590
1855
-
-
X
-
-
-
X
-
-
X
-
2875
2255
2070
630
1270
-
-
2590
1855
-
-
X
-
X
X
-
X
X
-
-
2875
2285
2070
630
1270
-
-
2590
1855
-
FC/FH 070 - GAS
X
-
X
-
-
-
-
-
-
X
2825
2255
1470
630
-
1230
1300
2210
-
-
-
X
X
-
-
-
-
-
-
X
2875
2255
2070
630
-
1400
1470
2590
1855
-
FC/FH 085 - Cooling only and heat pump
X
-
X
-
-
-
-
-
-
X
3785
2255
1495
630
1220
-
-
2830
2330
-
X
-
-
-
-
X
-
-
X
-
3785
2255
1495
630
1270
-
-
2830
2330
-
X
-
-
X
X
-
X
X
-
-
3785
2285
1495
630
1275
-
-
2830
2330
-
-
X
X
-
-
-
-
-
-
X
3835
2255
2080
630
1435
-
-
3230
2430
1870
-
X
-
-
-
X
-
-
X
-
3835
2255
2080
630
1485
-
-
3230
2430
1870
-
X
-
X
X
-
X
X
-
-
3835
2285
2080
630
1490
-
-
3230
2430
1870
FC/FH 085 - GAS
X
-
X
-
-
-
-
-
-
X
3785
2255
1495
630
-
1320
1390
2830
2330
-
-
X
X
-
-
-
-
-
-
X
3835
2255
2080
630
-
1535
1605
3230
2430
1870
FC/FH 100 - Cooling only and heat pump
X
-
X
-
-
-
-
-
-
X
3785
2255
1495
630
1280
-
-
2830
2330
-
X
-
-
-
-
X
-
-
X
-
3785
2255
1495
630
1320
-
-
2830
2330
-
X
-
-
X
X
-
X
X
-
-
3785
2285
1495
630
1320
-
-
2830
2330
-
-
X
X
-
-
-
-
-
-
X
3835
2255
2080
630
1495
-
-
3230
2430
1870
-
X
-
-
-
X
-
-
X
-
3835
2255
2080
630
1545
-
-
3230
2430
1870
-
X
-
X
X
-
X
X
-
-
3835
2285
2080
630
1545
-
-
3230
2430
1870
FC/FH 100 -
GAS
X
-
X
-
-
-
-
-
-
X
3785
2255
1495
630
-
1380
1450
2830
2330
-
-
X
X
-
-
-
-
-
-
X
3835
2255
2080
630
-
1595
1665
3230
2430
1870
HEIGHT
(mm)
HOOD
(mm)
WIDTH
(mm)
LENGTH
(mm)
Summary of Contents for ROOFTOP FLEXY FCA 100
Page 1: ...INSTALLATION OPERATING MAINTENANCE MANUAL ROOFTOP FLEXY English August 2003 ...
Page 2: ......
Page 33: ...IOM ROOF TOP FLEXY Series Page 31 AIR FLOW BALANCING AT 12 12 FAN ...
Page 34: ...Page 32 IOM ROOF TOP FLEXY Series AIR FLOW BALANCING AT 15 15 FAN ...
Page 35: ...IOM ROOF TOP FLEXY Series Page 33 AIR FLOW BALANCING AT 18 13 ...
Page 36: ...Page 34 IOM ROOF TOP FLEXY Series AIR FLOW BALANCING AT 18 18 FAN ...
Page 37: ...IOM ROOF TOP FLEXY Series Page 35 AIR FLOW BALANCING RDN 450 FAN ...
Page 38: ...Page 36 IOM ROOF TOP FLEXY Series AIR FLOW BALANCING ADN 355 FAN ...
Page 39: ...IOM ROOF TOP FLEXY Series Page 37 AIR FLOW BALANCING ADN 400 FAN ...
Page 40: ...Page 38 IOM ROOF TOP FLEXY Series AIR FLOW BALANCING ADN 450 FAN ...
Page 104: ...Page 102 IOM ROOF TOP FLEXY Series ELECTRICAL WIRING DIAGRAMS MAIN CURRENT DIAGRAM ...
Page 106: ...Page 104 IOM ROOF TOP FLEXY Series ELECTRICAL WIRING DIAGRAMS CLIMATIC CONTROLLER ...
Page 108: ...Page 106 IOM ROOF TOP FLEXY Series ELECTRICAL WIRING DIAGRAMS CLIMATIC INPUT FG FD ...
Page 112: ...Page 110 IOM ROOF TOP FLEXY Series ELECTRICAL WIRING DIAGRAMS GAS BURNER 180 Kw ...
Page 132: ...Page 130 IOM ROOF TOP FLEXY Series ISO 9001 CERTIFICATION ...
Page 133: ...IOM ROOF TOP FLEXY Series Page 131 PED CERTIFICATION OF CONFORMITY ...
Page 134: ...Page 132 IOM ROOF TOP FLEXY Series GLASS WOOL FIRE CLASS ...
Page 135: ...IOM ROOF TOP FLEXY Series Page 133 33 kW GAS BURNER CE CERTIFICATION OF CONFORMITY ...
Page 136: ...Page 134 IOM ROOF TOP FLEXY Series 60 kW GAS BURNER CE CERTIFICATION OF CONFORMITY ...
Page 137: ...IOM ROOF TOP FLEXY Series Page 135 120 kW GAS BURNER CE CERTIFICATION OF CONFORMITY ...
Page 138: ...Page 136 IOM ROOF TOP FLEXY Series 180 kW GAS BURNER CE CERTIFICATION OF CONFORMITY ...
Page 139: ...IOM ROOF TOP FLEXY Series Page 137 INSULATION FIRE CLASS ...
Page 140: ...Page 138 IOM ROOF TOP FLEXY Series INSULATION FIRE CLASS ...
Page 141: ......