Page 6
BLOWER DATA
SL297UH060NV36B BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1114
1237
+18%
1063
1168
+12%
1010
1106
+6%
951
1064
Factory Default
892
1003
–6%
837
942
–12%
761
869
–18%
693
809
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low
Medium-High
2
High
Low
Medium-Low
Medium-High
2
High
+
599
749
867
981
892
1057
1229
1404
Factory Default
549
656
754
866
775
958
1115
1279
–
475
609
680
773
708
854
1011
1147
SL297UH060NV36B BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1098
1229
+18%
1039
1168
+12%
992
1104
+6%
930
1051
Factory Default
885
996
–6%
822
937
–12%
773
878
–18%
717
817
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low
Medium-High
2
High
Low
Medium-Low
Medium-High
2
High
+
578
746
847
957
889
1042
1197
1364
Factory Default
556
665
764
864
799
949
1093
1249
–
485
593
706
783
721
845
988
1122
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 250 cfm.