Page 42
FIGURE 25
TYPICAL EXHAUST PIPE CONNECTIONS AND CONDENSATE TRAP INSTALLATION
TRANSITION
2”
2”
2”
3”
Use only the factory
−
supplied
trap. Trap can be installed on
either side of cabinet within 5 ft.
of the furnace.
TRAP
TOP VIEW
Exhaust
Air Intake
DO NOT transition
from smaller to larger
pipe size in horizontal
runs of exhaust pipe.
* When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible.
NOTE
−
Exhaust pipe and intake pipe must be the same diameter.
*2“
FIGURE 26
TYPICAL AIR INTAKE PIPE CONNECTIONS
2”
2”
TRANSITION
3”
TRANSITION
2”
3”
TRAP
Use only the factory
−
supplied
trap. Trap can be installed on
either side of cabinet within 5 ft.
of the furnace.
TOP VIEW
Exhaust
Air Intake
*2”
*2”
*2”
* When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible.
NOTE
−
Intake pipe and exhaust pipe must be the same diameter.