Installing Your Insert Pellet Stove
Model: Profile 30-lnsert: VENTING INTO AN EXISTING CHIMNEY
The Profile Insert may be installed in a
masonry or factory built fireplace as
shown to the right. When installing into a
masonry chimney, it is recommended
that the exhaust vent be extended to the
top of the chimney as shown to the lower
right. However, if the vent pipe does not
extend to the top of the chimney, the
pipe must extend a minimum of 18"
above the damper. You must seal the
damper area with a steel plate.
IMPORTANT NOTE!!
MAKE SURE THE CHIMNEY
AND FIREBOX ARE CLEAN AND
FREE OF SOOT AND ASHES
BEFORE INSTALLATION BEGINS.
FAILURE TO DO SO MAY
RESULT IN THE TRANSFER OF
SOOT INTO THE ROOM BY
WAY OF THE CONVECTION
FAN.
"Direct Vent"
The Vent Pipe Must Extend A Minimum
Of 18" Above The Damper. The
'
Chimney Must Not Be Corroded Or
Metal
Plate To
Provide
Seal
"Direct Connection"
(Not Allowed In Canada)
- Q��ed In Any Way For This Type Of
Installation To Be Permitted.
Clean
Out
Tee
Page 22
NOTE: For insert
installation in Canada
it is required that the
chimney be fully lined.
A Direct Vent May Be
Made Through The
Chimney Structure If
Local Codes Permit.
Pipe Support
18"
Min.
Clearance
I
I
I
I
:_§�'
: Min.
"Full Chimney Reline"
Recommended for ALL
Chimney installations
Clean
Out
Tee