FURNACE 

1F

URNACE 

2

ISO RELAY

THERMOST

AT

COOL TWIN ONLY

W1

R

C

Y1

Y2

G

W2

W1

R

C

Y1

Y2

G

W2

W1

R

C

Y1

Y2

G

W2

Figure 2. 

FURNACE 

1F

URNACE 

2

ISO RELAY

THERMOST

AT

FAN TWIN ONLY

W1

R

C

Y1

Y2

G

W2

W1

R

C

Y1

Y2

G

W2

W1

R

C

Y1

Y2

G

W2

Figure 3. 

Two-Stage Heating and Single-Stage Cooling with 

Single-Stage Thermostat

1.  Mount DPST relay(s) (supplied with kit) next to the 

blower control board of Furnace 1. Use kit supplied 

self-tapping screws to mount DPST relay(s) to the 

control bracket.

2.  Connect the thermostat with Furnace 1, Furnace 2, 

and the DPST relays as shown in Figure 1 through 

Figure 3. Use the female quick connect terminals 

supplied in kit and the proper length of 18 gauge wire 

(field supplied) to complete wiring.

3.  Set DIP switches of Furnace 1 and Furnace 2 control 

boards to same furnace mode DIP switch setting for 

single stage thermostat, 2nd stage timing setting 

and blower off setting. See the furnaces’ installation 

instructions for additional detail.

NOTE: 

Units are factory shipped with DIP switch 

settings for two-stage thermostat operation.

4.  After wiring is complete, cycle both high and low 

heating modes and cooling modes to verify both are 

working properly.