Symptom
or
error
FRU
or
action,
in
sequence
0210
Stuck
key—Stuck
key
on
keyboard
Enter
here
.
0211
Keyboard
error—Keyboard
not
working.
Run
interactive
tests
of
the
keyboard
and
the
auxiliary
input
device
.
0212
Keyboard
Controller
Failed—Keyboard
controller
failed
test.
Replace
keyboard
controller.
.
0213
Keyboard
locked—Unlock
key
switch
Unlock
the
system
to
proceed
.
0220
Monitor
type
does
not
match
CMOS
—Monitor
type
not
correctly
identified
in
Setup
Load
Setup
Defaults
in
BIOS
Setup
Utility.
0230
Shadow
Ram
Failed
at
offset:
nnnn—Shadow
RAM
failed
at
offset
nnnn
of
the
64k
block
at
which
the
error
was
detected.
System
board
.
0231
System
RAM
Failed
at
offset:
nnnn—System
RAM
failed
at
offset
nnnn
of
in
the
64k
block
at
which
the
error
was
detected
1.
DIMM
.
2.
System
board.
0232
Extended
RAM
Failed
at
offset:
nnnn
—Extended
memory
not
working
or
not
configured
properly
at
offset
nnnn..
1.
DIMM
.
2.
System
board.
0250
System
battery
is
dead
—The
CMOS
clock
battery
indicator
shows
the
battery
is
dead
Replace
the
backup
battery
and
run
BIOS
Setup
Utility
to
reset
the
time
and
date
.
0251
System
CMOS
checksum
bad
—Default
configuration
used.
Replace
the
backup
battery
and
run
BIOS
Setup
Utility
to
reset
the
time
and
date
.
0252
Password
checksum
bad—The
password
is
cleared.
Reset
the
password
by
running
BIOS
Setup
Utility.
0260
System
timer
error—The
timer
test
failed
1.
Replace
the
backup
battery
and
run
BIOS
Setup
Utility
to
reset
the
time
and
date
.
2.
System
board.
(continued)
Symptom-to-FRU
index
62
MT1864/1865/2525/2526/2527/2528