Symptom
or
error
FRU
or
action,
in
sequence
0187
EAIA
data
access
error—The
access
to
EEPROM
is
failed.
System
board
.
0188
Invalid
RFID
serialization
information
area
or
bad
CRC2—The
EEPROM
checksum
is
not
correct.
System
board
.
0189
Invalid
RFID
configuration
information
area—The
EEPROM
checksum
is
not
correct.
System
board
.
0190
Critical
low-battery
error
1.
Charge
the
battery
pack
.
2.
Battery
pack.
0191
System
Security
—
Invalid
remote
change
requested.
The
system
configuration
change
has
failed.
Confirm
the
operation
and
try
again.
To
clear
the
error,
enter
the
BIOS
Setup
Utility.
0199
System
security
—
IBM
security
password
retry
count
exceeded.
1.
Confirm
supervisor
password
and
try
again
.
2.
Run
BIOS
Setup
Utility
.
01C9
More
than
one
Ethernet
devices
are
found.
Remove
one
of
them.
Press
<Esc>
to
continue.
1.
Remove
either
a
Mini
PCI
Ethernet
card
or
an
Ethernet
daughter
card;
or
press
Esc
to
ignore
the
warning
message
.
2.
System
board.
0200
Hard
disk
error—The
hard
disk
is
not
working.
1.
Reseat
the
hard
disk
drive
.
2.
Load
Setup
Defaults
in
BIOS
Setup
Utility.
3.
Hard
disk
drive.
4.
System
board.
021x
Keyboard
error
Run
interactive
tests
of
the
keyboard
and
the
auxiliary
input
device
.
0230
Shadow
RAM
error—Shadow
RAM
fails
at
offset
nnnn.
System
board
.
0231
System
RAM
error—System
RAM
fails
at
offset
nnnn.
1.
DIMM
.
2.
System
board.
0232
Extended
RAM
error—Extended
RAM
fails
at
offset
nnnn.
1.
DIMM
.
2.
System
board.
Symptom-to-FRU
index
ThinkPad
G40,
G41
53
Summary of Contents for 2384EHU - ThinkPad G40 2384
Page 1: ...ThinkPad Computer Hardware Maintenance Manual July 2005 This manual supports ThinkPad G40 G41 ...
Page 6: ...2 ThinkPad G40 G41 ...
Page 28: ...Laser compliance statement 24 ThinkPad G40 G41 ...
Page 46: ...Checkout guide 42 ThinkPad G40 G41 ...
Page 150: ...LCD FRUs Parts list 146 ThinkPad G40 G41 ...
Page 163: ...Trademarks ThinkPad G40 G41 159 ...