8. Close the microprocessor retainer and clamp it with the small handle.
9. Place the heat sink into position and replace the 4 screws to secure the heat sink to the system board.
10. Reconnect the heat sink fan cable.
11. Go to “Completing the FRU replacement” on page 106.
Replacing the system board
CAUTION:
The heat sink, microprocessor, and memory module might be very hot. Turn off the
computer and wait three to five minutes to let the computer cool before opening the computer cover.
Attention
Do not open your computer or attempt any repair before reading and understanding the “Important safety information”
in the
ThinkStation Safety and Warranty Guide
that came with your computer. To obtain a copy of the
ThinkStation
Safety and Warranty Guide
, go to:
http://www.lenovo.com/support.
Note:
When replacing the system board a new retention module for the microprocessor heat sink is required.
Make sure you have a new retention module before beginning this procedure.
This section provides instructions on how to remove and install the system board.
To replace the system board:
1. Open the cover. See “Removing the cover” on page 76.
2. Lay the computer on its side for easier access to the system board.
3. Remove the hard disk drive fan. See “Replacing the hard disk drive fan assembly” on page 98.
4. Remove any adapter cards installed in the PCI connectors. See “Replacing a PCI adapter card” on
page 84.
5. Remove the memory modules from the failing system board.
6. Remove the heat sink from the failing system board. See “Replacing the heat sink” on page 88.
7. Note the location of all cable connections on the system board and disconnect all cables. See “Locating
parts on the system board ” on page 111.
8. Remove the nine screws that secure the system board to the chassis, following the sequence shown in
the figure:
122
ThinkStation Hardware Maintenance Manual
Summary of Contents for 4157 - ThinkStation S20 - 2 GB RAM
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkStation Hardware Maintenance Manual ...
Page 56: ...50 ThinkStation Hardware Maintenance Manual ...
Page 80: ...74 ThinkStation Hardware Maintenance Manual ...
Page 93: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Page 124: ...118 ThinkStation Hardware Maintenance Manual ...
Page 264: ...258 ThinkStation Hardware Maintenance Manual ...
Page 268: ...262 ThinkStation Hardware Maintenance Manual ...
Page 274: ...268 ThinkStation Hardware Maintenance Manual ...
Page 275: ......
Page 276: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...